pubmed:abstractText
Since the introduction of hemodialysis procedure several attempts have been made to elucidate the material tissue interaction in order to evaluate the behaviour of immunosystem cellular and humoral responses to the material of patients on renal replacement therapy. Biochemical and sierological parameters have been considered as method for assessment of the best compatible dialysis. Nevertheless blood tests don't probably reflect the most important symptoms of clinical relevance. Thus we have applied bioelectrical impedance to assess the whole procedure/patient system. Resistance (R) changes during hemodialysis resulted strictly inversely correlated to the body weight variations during HD session (R < 0.96). Reactance (Xc) has also shown a progressive increase associated with an increment of phase angle, while Xc during clinical events such as hypotension, vomiting or cramps showed some transient falls. Also nutritional status and clinical well-being manifested a close relationship with bioelectrical parameters. It is therefore our feeling that BIA monitoring will provide a feasible tool to assess dialysis adequacy, of which biocompatibility represent a crucial aspect.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Nov
pubmed:issn
0391-3988
pubmed:author
pubmed:issnType
Print
pubmed:volume
18
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
712-5
pubmed:dateRevised
2006-11-15
pubmed:meshHeading
pubmed-meshheading:8964633-Adult, pubmed-meshheading:8964633-Aged, pubmed-meshheading:8964633-Bicarbonates, pubmed-meshheading:8964633-Biocompatible Materials, pubmed-meshheading:8964633-Blood Chemical Analysis, pubmed-meshheading:8964633-Body Water, pubmed-meshheading:8964633-Body Weight, pubmed-meshheading:8964633-Buffers, pubmed-meshheading:8964633-Colic, pubmed-meshheading:8964633-Electric Impedance, pubmed-meshheading:8964633-Electrodes, pubmed-meshheading:8964633-Extracellular Space, pubmed-meshheading:8964633-Feasibility Studies, pubmed-meshheading:8964633-Female, pubmed-meshheading:8964633-Humans, pubmed-meshheading:8964633-Hypotension, pubmed-meshheading:8964633-Male, pubmed-meshheading:8964633-Middle Aged, pubmed-meshheading:8964633-Nutritional Status, pubmed-meshheading:8964633-Renal Dialysis, pubmed-meshheading:8964633-Technology Assessment, Biomedical, pubmed-meshheading:8964633-Uremia, pubmed-meshheading:8964633-Vomiting
pubmed:year
1995
pubmed:articleTitle
Assessment of the best compatible dialysis system: feasible application for bioelectrical impedance.
pubmed:affiliation
Department of Nephrology and Dialysis, Ospedale Umberto I, Venezia-Mestre, Italy.
pubmed:publicationType