Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
3
|
pubmed:dateCreated |
1996-12-12
|
pubmed:abstractText |
The incidence of penetrating skin wounds and needle penetration of gloves during operation was studied in orthopaedic surgeons. Significant hand wounds were found in 11% of surgeons before operations. Glove penetration during closure of the deep tissues occurred in 16% of outer gloves and 6% of inner gloves when standard needle points were used. The surgeon sustained a needle-stick injury in 6% of this group. When a needle with a protective point was used, there were no glove perforations. This simple precaution reduces the risk of transmission of blood-borne disease during operation.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:issn |
0341-2695
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
20
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
132-3
|
pubmed:dateRevised |
2004-11-17
|
pubmed:meshHeading |
pubmed-meshheading:8832312-Equipment Design,
pubmed-meshheading:8832312-Gloves, Surgical,
pubmed-meshheading:8832312-Hand Injuries,
pubmed-meshheading:8832312-Hip Prosthesis,
pubmed-meshheading:8832312-Humans,
pubmed-meshheading:8832312-Incidence,
pubmed-meshheading:8832312-Needles,
pubmed-meshheading:8832312-Needlestick Injuries,
pubmed-meshheading:8832312-Sutures
|
pubmed:year |
1996
|
pubmed:articleTitle |
Needle stick injury. Reducing the risk.
|
pubmed:affiliation |
Orthopaedic Department, Cappagh Orthopaedic Hospital, Finglas, Dublin, Eire.
|
pubmed:publicationType |
Journal Article,
Clinical Trial,