pubmed:abstractText |
We describe a simple, specific, and sensitive reversed-phase HPLC method with automated solid-phase extraction (SPE) for analyzing alprazolam, clonazepam, and nitrazepam concentrations in human serum or plasma. We prepare samples and calibrators with an automated sample preparer, using 100-mg Bond-Elut C18 SPE columns. The HPLC method uses isocratic elution with acetonitrile:methanol:dipotassium hydrogen phosphate, 10 nmol/L, pH 3.7 (30:2:100 by vol), at a flow rate of 1.5 mL/min to separate the drugs. We detect the benzodiazepines with diode-array detector at 240 nm; analyses of peak purity are performed at 210-365 nm. The recoveries were between 94% and 100%. The intraassay and interassay CVs were between 1.0% and 4.1%. The detection limit is 5 nmol/L. The antiepileptic and antidepressant drugs tested did not interfere with the assay. We developed the method for use in a clinical laboratory for therapeutic drug monitoring.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical |
http://linkedlifedata.com/resource/pubmed/chemical/Alprazolam,
http://linkedlifedata.com/resource/pubmed/chemical/Antidepressive Agents,
http://linkedlifedata.com/resource/pubmed/chemical/Benzodiazepines,
http://linkedlifedata.com/resource/pubmed/chemical/Clonazepam,
http://linkedlifedata.com/resource/pubmed/chemical/Nitrazepam,
http://linkedlifedata.com/resource/pubmed/chemical/Phenothiazines
|
pubmed:status |
MEDLINE
|
pubmed:month |
Sep
|
pubmed:issn |
0009-9147
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
42
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
1412-6
|
pubmed:dateRevised |
2008-11-21
|
pubmed:meshHeading |
pubmed-meshheading:8787697-Alprazolam,
pubmed-meshheading:8787697-Antidepressive Agents,
pubmed-meshheading:8787697-Automation,
pubmed-meshheading:8787697-Benzodiazepines,
pubmed-meshheading:8787697-Chromatography, High Pressure Liquid,
pubmed-meshheading:8787697-Clonazepam,
pubmed-meshheading:8787697-Humans,
pubmed-meshheading:8787697-Nitrazepam,
pubmed-meshheading:8787697-Phenothiazines,
pubmed-meshheading:8787697-Sensitivity and Specificity
|
pubmed:year |
1996
|
pubmed:articleTitle |
Analysis of low-dose benzodiazepines by HPLC with automated solid-phase extraction.
|