Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
6
|
pubmed:dateCreated |
1996-10-29
|
pubmed:abstractText |
We report the preliminary results of a prospective study demonstrating tetrofosmin uptake in surgically and histologically proven parathyroid adenomas. In ten patients with primary chronic hyperparathyroidism, parathyroid imaging was performed using (1) technetium-99m methoxyisobutylisonitrile (MIBI) and (2) 99mTc-1, 2-bis(bis(2-ethoxyethyl)phosphino)ethane (tetrofosmin) within a time interval of 3-5 days. Both tracers correctly identified the parathyroid adenomas by focal prolonged tracer retention. On visual inspection image contrast was generally higher with MIBI than with tetrofosmin in all the patients studied. Tetrofosmin showed a slower elimination from the parathyroid adenomas than MIBI in six of the ten cases. Our preliminary results show that tetrofosmin, like MIBI, as a feasible, sensitive tracer for parathyroid scintigraphy. For routine use, the rapid kit preparation without heating and the lower radiation dose to the patient make tetrofosmin an alternative tracer for parathyroid scintigraphy. Further evaluation is needed to determine which of the two tracers is the more sensitive for the detection of parathyroid adenomas, and which tracer properties better reflect the degree of endocrine activity.
|
pubmed:commentsCorrections | |
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical |
http://linkedlifedata.com/resource/pubmed/chemical/Organophosphorus Compounds,
http://linkedlifedata.com/resource/pubmed/chemical/Organotechnetium Compounds,
http://linkedlifedata.com/resource/pubmed/chemical/Technetium Tc 99m Sestamibi,
http://linkedlifedata.com/resource/pubmed/chemical/technetium Tc 99m...
|
pubmed:status |
MEDLINE
|
pubmed:month |
Jun
|
pubmed:issn |
0340-6997
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
23
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
693-6
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:8662105-Adenoma,
pubmed-meshheading:8662105-Aged,
pubmed-meshheading:8662105-Female,
pubmed-meshheading:8662105-Humans,
pubmed-meshheading:8662105-Image Processing, Computer-Assisted,
pubmed-meshheading:8662105-Male,
pubmed-meshheading:8662105-Middle Aged,
pubmed-meshheading:8662105-Organophosphorus Compounds,
pubmed-meshheading:8662105-Organotechnetium Compounds,
pubmed-meshheading:8662105-Parathyroid Neoplasms,
pubmed-meshheading:8662105-Prospective Studies,
pubmed-meshheading:8662105-Technetium Tc 99m Sestamibi
|
pubmed:year |
1996
|
pubmed:articleTitle |
Parathyroid scintigraphy: comparison of technetium-99m methoxyisobutylisonitrile and technetium-99m tetrofosmin studies.
|
pubmed:affiliation |
Division of Nuclear Medicine, Department of Radiology, University Hospital Graz, Austria.
|
pubmed:publicationType |
Journal Article,
Comparative Study
|