Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
2
pubmed:dateCreated
1996-7-26
pubmed:abstractText
Continuous monitoring of renal cortical blood flow (RCBF) in the perioperative setting of aortic or renal vascular surgery could facilitate the early detection of vascular complications, possibly resulting in a reduction of postoperative renal failure. A new prototype system for measurement of parenchymous organ perfusion based on the principle of thermal diffusion ("TD"-Thermal Diffusion Electrode, Thermal Technologies Inc., Cambridge, MA, USA) was used for RCBF measurements in the outer cortex of the porcine kidney. We validated the sensitivity of the device to detect renal blood flow impairment, comparing TD flow data with renal artery blood flow values (RABF), measured by ultrasonic flow probes. The hypothesis was tested that acute disturbances of RCBF, induced by a variable degree of renal artery stenosis, can be immediately detected and continuously monitored by TD measurements in the porcine renal cortex. Mean baseline RCBF measured by TD electrodes was 68.1 +/- 25.0 ml/100 g/min. Mean baseline RABF was 102.1 +/- 26.6 ml/min. Controlled induction of a variable degree of renal arterial occlusion by implanted vascular balloon occluders was always followed by an immediate and proportional decline of RCBF, as measured by TD. Flow data obtained with both methods were significantly correlated by linear regression (r=.82, r2=.68; P < 0.0001). Dynamic changes of RABF in the time course of renal artery partial/total occlusion and arterial flow release could be continuously followed by detection of corresponding flow changes of RCBF. We conclude that the TD system investigated in the current study allows a continuous and sensitive determination of porcine renal cortex perfusion. A clinical evaluation of the method, e.g., in the perioperative setting of aortic or renal transplantation surgery, now appears to be justified.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:month
Mar
pubmed:issn
0022-4804
pubmed:author
pubmed:issnType
Print
pubmed:volume
61
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
531-6
pubmed:dateRevised
2006-9-18
pubmed:meshHeading
pubmed:year
1996
pubmed:articleTitle
Continuous measurement of porcine renal cortex microcirculation with enhanced thermal diffusion technology.
pubmed:affiliation
Department of Surgery, University of Heidelberg, Germany.
pubmed:publicationType
Journal Article