Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
5
|
pubmed:dateCreated |
1993-6-21
|
pubmed:abstractText |
Liver biopsy is a frequently utilized diagnostic tool at a liver transplant center. It is occasionally utilized prior to OLTx to determine whether or not a potential recipient either has tumor or a disease process that has some chance of spontaneous recovery without OLTx. Following OLTx, it is often utilized to determine the need to alter a recipient's immunosuppression regimen or gauge the response to a recent change in immunosuppression. At the University of Pittsburgh Medical Center, adult liver transplant patients have been biopsied using 3 different techniques based upon the physician's (Tru-cut needle) or surgeon's (suction needle) personal choice and whether or not it has been the intent of the biopsy to obtain tissue from a focal lesion within a liver. In the latter cases, ultrasound guidance and an automated biopsy needle are used. In the former, either a suction-type needle (Jamshidi) or a cutting needle (Tru-cut) has been used. During the period between January 1, 1989, and December 31, 1991, a total of 12,750 liver biopsies have been done on patients admitted to the adult transplant service at this institution. Of these, 8500 were performed with a suction needle, 4195 were performed using a cutting needle, and 55 were performed under ultrasound guidance using an automated cutting needle. A total of 26 major complications occurred--19 with the suction needle (0.22%); 6 with the cutting needle (0.14%), and 2 using ultrasound guidance and an automatic cutting needle (3.6%). Nine of these 26 complications required surgical intervention consisting of a thoracotomy or laparotomy; 4 required the insertion of a chest tube and two required hepatic artery embolization. Based upon these data obtained at a large transplant center, it can be concluded that, in general: (1) a liver biopsy can be done safely in liver transplant recipients; (2) an overall low rate of major complications occurs varying from 0.1 to 3.6% depending upon the type of needle and other circumstances relating to the biopsy procedure; (3) complications, when they occur, are morbid and often necessitate either additional surgical or interventional radiologic procedures.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
May
|
pubmed:issn |
0041-1337
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
55
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
1087-90
|
pubmed:dateRevised |
2004-11-17
|
pubmed:meshHeading | |
pubmed:year |
1993
|
pubmed:articleTitle |
Liver biopsy. Its safety and complications as seen at a liver transplant center.
|
pubmed:affiliation |
Department of Surgery, University of Pittsburgh School of Medicine, Pennsylvania 15213.
|
pubmed:publicationType |
Journal Article
|