Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
2
|
pubmed:dateCreated |
1993-6-7
|
pubmed:abstractText |
A prospective in vivo study of 50 intraocular lenses was done to document the long-term results and biocompatibility of heparin-surface-modified poly(methyl methacrylate) posterior chamber lenses. Continuous curvilinear capsulorhexis and phacoemulsification were performed throughout and examinations were by slit-lamp and specular microscopy. Decentrations of more than 1 mm were seen in 4% of eyes. Stress folds from the haptic traction forces were detected in 16%. A posterior capsulotomy was performed in 10% because of fibrosis or Elschnig pearl formation. Fine fibers were found on the lens surface in 76%. During the first postoperative days only a moderate number of fibroblast-like cells was observed. Foreign-body giant cells were seen in 8%. All cases with foreign-body giant cells had posterior synechias. Visual performance and clinical results were comparable to those of other well-approved intraocular lenses. The low percentage of cellular reaction on the lens surface suggests good biocompatibility.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Mar
|
pubmed:issn |
0886-3350
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
19
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
258-62
|
pubmed:dateRevised |
2004-11-17
|
pubmed:meshHeading |
pubmed-meshheading:8487171-Adult,
pubmed-meshheading:8487171-Aged,
pubmed-meshheading:8487171-Aged, 80 and over,
pubmed-meshheading:8487171-Biocompatible Materials,
pubmed-meshheading:8487171-Cataract Extraction,
pubmed-meshheading:8487171-Female,
pubmed-meshheading:8487171-Fibroblasts,
pubmed-meshheading:8487171-Foreign-Body Reaction,
pubmed-meshheading:8487171-Giant Cells,
pubmed-meshheading:8487171-Heparin,
pubmed-meshheading:8487171-Humans,
pubmed-meshheading:8487171-Lenses, Intraocular,
pubmed-meshheading:8487171-Longitudinal Studies,
pubmed-meshheading:8487171-Male,
pubmed-meshheading:8487171-Methylmethacrylate,
pubmed-meshheading:8487171-Methylmethacrylates,
pubmed-meshheading:8487171-Middle Aged,
pubmed-meshheading:8487171-Prospective Studies,
pubmed-meshheading:8487171-Prosthesis Design,
pubmed-meshheading:8487171-Treatment Outcome,
pubmed-meshheading:8487171-Visual Acuity
|
pubmed:year |
1993
|
pubmed:articleTitle |
Long-term results and biocompatibility of heparin-surface-modified intraocular lenses.
|
pubmed:affiliation |
1. Universität Augenklinik Wien, Vienna, Austria.
|
pubmed:publicationType |
Journal Article
|