pubmed-article:8458673pubmed:abstractTextA self-tuning, nonlinear controller was developed to drive portable or implantable micro-pumps for blood glucose control in diabetic subjects. The parameter estimation is based on a recursive least-square algorithm applied to a discrete time simplified mathematical model of the glucose system; the controller, which is integrated with the estimator, uses an extended minimum-variance method. The software was designed to drive a micro-controller wearable unit, operating with different kinds of glucose sensors, in order to perform chemical and biological experimentations. Some strategies were introduced to avoid hypoglycaemia, even tolerating a reduction in control speed and accuracy. The whole system was tested in a simulation study, performed on a mathematical model implemented on a personal computer. The tests were performed while simulating different controller structures and settings, and patient responses. They showed a satisfactory control behaviour, mostly as far as stability and robustness are concerned, in all simulated conditions.lld:pubmed
pubmed-article:8458673pubmed:languageenglld:pubmed
pubmed-article:8458673pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:8458673pubmed:citationSubsetIMlld:pubmed
pubmed-article:8458673pubmed:statusMEDLINElld:pubmed
pubmed-article:8458673pubmed:monthJanlld:pubmed
pubmed-article:8458673pubmed:issn0391-3988lld:pubmed
pubmed-article:8458673pubmed:authorpubmed-author:BrunettiPPlld:pubmed
pubmed-article:8458673pubmed:authorpubmed-author:SanteusanioFFlld:pubmed
pubmed-article:8458673pubmed:authorpubmed-author:SartiEElld:pubmed
pubmed-article:8458673pubmed:authorpubmed-author:CobelliCClld:pubmed
pubmed-article:8458673pubmed:authorpubmed-author:FabiettiP GPGlld:pubmed
pubmed-article:8458673pubmed:authorpubmed-author:CrucianiPPlld:pubmed
pubmed-article:8458673pubmed:authorpubmed-author:FilippucciFFlld:pubmed
pubmed-article:8458673pubmed:issnTypePrintlld:pubmed
pubmed-article:8458673pubmed:volume16lld:pubmed
pubmed-article:8458673pubmed:ownerNLMlld:pubmed
pubmed-article:8458673pubmed:authorsCompleteYlld:pubmed
pubmed-article:8458673pubmed:pagination51-7lld:pubmed
pubmed-article:8458673pubmed:dateRevised2006-11-15lld:pubmed
pubmed-article:8458673pubmed:meshHeadingpubmed-meshheading:8458673-...lld:pubmed
pubmed-article:8458673pubmed:meshHeadingpubmed-meshheading:8458673-...lld:pubmed
pubmed-article:8458673pubmed:meshHeadingpubmed-meshheading:8458673-...lld:pubmed
pubmed-article:8458673pubmed:meshHeadingpubmed-meshheading:8458673-...lld:pubmed
pubmed-article:8458673pubmed:meshHeadingpubmed-meshheading:8458673-...lld:pubmed
pubmed-article:8458673pubmed:meshHeadingpubmed-meshheading:8458673-...lld:pubmed
pubmed-article:8458673pubmed:meshHeadingpubmed-meshheading:8458673-...lld:pubmed
pubmed-article:8458673pubmed:year1993lld:pubmed
pubmed-article:8458673pubmed:articleTitleA simulation study on a self-tuning portable controller of blood glucose.lld:pubmed
pubmed-article:8458673pubmed:affiliationMedical Pathology Institute, Bioengineering Laboratory, University of Perugia, Italy.lld:pubmed
pubmed-article:8458673pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:8458673pubmed:publicationTypeResearch Support, Non-U.S. Gov'tlld:pubmed