pubmed:abstractText |
After a short outline of the history of creatinine determination methods we describe the development of a dry-reagent-carrier system for the reflometric determination of the creatinine concentration in blood, plasma, serum and urine (Reflotron Creatinine (new)). The method is based on a sequence of enzymatically catalyzed reactions producing H2O2, but which in contrast to the previously used procedure do not lead to the formation of creatine as an intermediate. Hence, pretreatment of sample material to eliminate endogenous creatine is no longer necessary. In the indicator reaction, use is made of an imidazole derivative as the chromogen. The dye formed in the presence of peroxidase can be measured by reflectance photometry beyond the long-wave absorption bands of haemoglobin and bilirubin at 642 nm. We present in detail the results of the multicentre evaluation of the analytical properties of this new test principle. The data obtained show that Reflotron Creatinine (new) correlates well with the routine method Creatinine PAP, which was used as a comparison method, with respect to accuracy and precision and even surpasses it with respect to specificity. Advantages over the first generation of Reflotron Creatinine are: shorter reaction time, longer stability of the reagent carrier, no interference by bilirubin and reduced interference by haemoglobin.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
May
|
pubmed:issn |
0939-4974
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
31
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
335-46
|
pubmed:dateRevised |
2007-11-15
|
pubmed:meshHeading |
pubmed-meshheading:8357943-Blood Chemical Analysis,
pubmed-meshheading:8357943-Creatinine,
pubmed-meshheading:8357943-Evaluation Studies as Topic,
pubmed-meshheading:8357943-Humans,
pubmed-meshheading:8357943-Indicators and Reagents,
pubmed-meshheading:8357943-Reproducibility of Results,
pubmed-meshheading:8357943-Sensitivity and Specificity,
pubmed-meshheading:8357943-Spectrophotometry
|
pubmed:year |
1993
|
pubmed:articleTitle |
Development and evaluation of a reagent carrier with a new reaction sequence for the determination of creatinine in blood, plasma, serum and urine.
|
pubmed:affiliation |
Boehringer Mannheim GmbH, Mannheim, Germany.
|
pubmed:publicationType |
Journal Article,
Comparative Study,
Multicenter Study
|