Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
4
pubmed:dateCreated
1994-5-24
pubmed:abstractText
Durable, covalently bonded, heparin-coated cardiopulmonary bypass (CPB) circuits with oxygenators have been developed. Proposed advantages of heparin-coated CPB circuits include improved biocompatibility and thromboresistance. The purpose of this study was to evaluate our experience with heparin-coated CPB circuits in 20 patients. Heparin was given to maintain an activated clotting time equal to or greater than 200 seconds, while flow rates were kept equal to or greater than 2 L/min. Indications for use of this circuit included recent stroke, posttraumatic injuries, recent gastrointestinal bleeding, protamine allergies, combined cardiac and noncardiac procedures, and ventricular assist. Mean heparin dosage was 0.50 +/- 0.18 mg/kg and protamine dosage was 57.14 +/- 39.36 mg. Postoperative blood loss and transfusion requirements were minimal. Postoperative complement levels of C3a and C5a were normal, suggesting excellent biocompatibility. There were no deaths or perioperative complications. Heparin-coated CPB circuits using a pump oxygenator can be used safely with low-dose heparin administration in select patients requiring CPB.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
AIM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Apr
pubmed:issn
0003-4975
pubmed:author
pubmed:issnType
Print
pubmed:volume
57
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
815-8; discussion 818-9
pubmed:dateRevised
2005-11-17
pubmed:meshHeading
pubmed-meshheading:8166524-Adolescent, pubmed-meshheading:8166524-Adult, pubmed-meshheading:8166524-Aged, pubmed-meshheading:8166524-Aged, 80 and over, pubmed-meshheading:8166524-Biocompatible Materials, pubmed-meshheading:8166524-Blood Flow Velocity, pubmed-meshheading:8166524-Blood Loss, Surgical, pubmed-meshheading:8166524-Blood Transfusion, pubmed-meshheading:8166524-Cardiopulmonary Bypass, pubmed-meshheading:8166524-Complement C3a, pubmed-meshheading:8166524-Complement C5a, pubmed-meshheading:8166524-Drug Monitoring, pubmed-meshheading:8166524-Durable Medical Equipment, pubmed-meshheading:8166524-Equipment Design, pubmed-meshheading:8166524-Female, pubmed-meshheading:8166524-Heparin, pubmed-meshheading:8166524-Humans, pubmed-meshheading:8166524-Male, pubmed-meshheading:8166524-Materials Testing, pubmed-meshheading:8166524-Middle Aged, pubmed-meshheading:8166524-Protamines, pubmed-meshheading:8166524-Whole Blood Coagulation Time
pubmed:year
1994
pubmed:articleTitle
Safe use of heparin-coated bypass circuits incorporating a pump-oxygenator.
pubmed:affiliation
Department of Surgery, West Virginia University, Morgantown.
pubmed:publicationType
Journal Article