Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
4 Pt 2
|
pubmed:dateCreated |
1994-5-19
|
pubmed:abstractText |
The identification of patients who benefit most from implantable cardioverter defibrillator (ICD) therapy is of great interest. To find out if clinical variables, the signal-averaged electrocardiogram, and electrophysiologic study predict occurrence of appropriate ICD discharges and death, we followed-up on 76 patients after implantation of a transvenous ICD. During a mean follow-up period of 18.2 +/- 6.4 months, 29 patients (38.6%) experienced at least one appropriate episode. When these patients were compared with those who had either no therapy or inappropriate episodes, three variables were found to be significant in the identification of patients who experienced appropriate discharges: (1) The mean ejection fraction of patients who received appropriate discharges was 35.4% +/- 13.5% versus 45.1% +/- 15.3% in the other group (p < 0.05); (2) patients with appropriate therapy had sustained monomorphic ventricular tachycardia that was more likely to be inducible (75.9% vs 21.2%, p < 0.01); and (3) in patients with appropriate therapy ventricular fibrillation was less likely to be inducible (10.3% vs 25.5%, p < 0.05). The signal-averaged electrocardiograms were more often abnormal, but the differences were not significant. The total mortality rate in our patient group was 7.8%, with nonsudden cardiac death in four patients, noncardiac death in one patient, and sudden death in one patient. In our patient group a lower ejection fraction and inducible sustained monomorphic ventricular tachycardia were predictors of future ICD discharge after implantation. The survival rate after transvenous ICD implantation is excellent; a longer follow-up period is necessary to further define predictors of total mortality rate.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
AIM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Apr
|
pubmed:issn |
0002-8703
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
127
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
1086-9
|
pubmed:dateRevised |
2006-2-27
|
pubmed:meshHeading |
pubmed-meshheading:8160585-Cardiac Pacing, Artificial,
pubmed-meshheading:8160585-Death, Sudden, Cardiac,
pubmed-meshheading:8160585-Defibrillators, Implantable,
pubmed-meshheading:8160585-Electrocardiography,
pubmed-meshheading:8160585-Female,
pubmed-meshheading:8160585-Follow-Up Studies,
pubmed-meshheading:8160585-Humans,
pubmed-meshheading:8160585-Male,
pubmed-meshheading:8160585-Middle Aged,
pubmed-meshheading:8160585-Risk Factors,
pubmed-meshheading:8160585-Signal Processing, Computer-Assisted,
pubmed-meshheading:8160585-Stroke Volume,
pubmed-meshheading:8160585-Survival Rate,
pubmed-meshheading:8160585-Tachycardia, Ventricular,
pubmed-meshheading:8160585-Time Factors,
pubmed-meshheading:8160585-Treatment Outcome,
pubmed-meshheading:8160585-Ventricular Fibrillation
|
pubmed:year |
1994
|
pubmed:articleTitle |
Predictors of outcome in patients with implantable transvenous cardioverter defibrillators.
|
pubmed:affiliation |
Department of Cardiology, University of Bonn, Germany.
|
pubmed:publicationType |
Journal Article
|