pubmed:abstractText |
The Tono-Pen XL (Bio-Rad, Santa Ana, CA) was compared with manometer readings for intraoperative measurement of intraocular pressure (IOP) in 40 eyes of 40 consecutive patients after vitrectomy, lensectomy, and fluid-air exchange. Tono-Pen readings corresponding to manometer readings of 10, 20, 30, 40, and 50 mmHg were obtained in a masked fashion with a randomized sequence of manometer readings. A correlation was obtained between the manometer and Tono-Pen readings (r = 0.96 in emmetropic eyes and r = 0.93 in myopic eyes). The regression curve that represents the calibration curve of Tono-Pen in terms of the manometer readings for air-filled vitrectomized eyes was obtained. Any Tono-Pen reading can be easily translated into the corresponding manometer reading by referring to the curve. The Tono-Pen can therefore be effectively used to accurately determine intraoperative IOP in eyes undergoing vitrectomy, lensectomy, and fluid-air exchange.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:issn |
0275-004X
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
13
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
307-11
|
pubmed:dateRevised |
2006-12-15
|
pubmed:meshHeading |
pubmed-meshheading:8115731-Adolescent,
pubmed-meshheading:8115731-Adult,
pubmed-meshheading:8115731-Aged,
pubmed-meshheading:8115731-Air,
pubmed-meshheading:8115731-Aphakia, Postcataract,
pubmed-meshheading:8115731-Cataract Extraction,
pubmed-meshheading:8115731-Child,
pubmed-meshheading:8115731-Child, Preschool,
pubmed-meshheading:8115731-Humans,
pubmed-meshheading:8115731-Intraocular Pressure,
pubmed-meshheading:8115731-Manometry,
pubmed-meshheading:8115731-Middle Aged,
pubmed-meshheading:8115731-Monitoring, Intraoperative,
pubmed-meshheading:8115731-Prospective Studies,
pubmed-meshheading:8115731-Random Allocation,
pubmed-meshheading:8115731-Reproducibility of Results,
pubmed-meshheading:8115731-Tonometry, Ocular,
pubmed-meshheading:8115731-Vitrectomy
|
pubmed:year |
1993
|
pubmed:articleTitle |
Intraoperative measurement of intraocular pressure in vitrectomized aphakic air-filled eyes using the Tono-Pen XL.
|
pubmed:affiliation |
Vitreoretinal Department, Sankara Nethralaya, Medical Research Foundation, Madras, India.
|
pubmed:publicationType |
Journal Article,
Comparative Study,
Research Support, Non-U.S. Gov't
|