Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
7-8
|
pubmed:dateCreated |
1995-1-12
|
pubmed:abstractText |
In 78 patients undergoing laparotomy suturing was carried out using absorbable thread (polyglyconate - Maxon) with eyelet to obtain a continuous knot-free suture according to Smead Jones' technique. A prospective study was made of all surgical wounds three months after the operation to evaluate the reliability of this technique. On examination, wounds were fully healed in 98% of patients. Less than 2% of patients revealed infections, dehiscence or anomalous granulations of the wound. No laparocele were observed at the time of control using this method. Continuous suture using a trimethylene polyglyconate (Maxon) thread with eyelet according to the Smead Jones technique was found to be safe and effective. A follow-up after a longer interval will be performed in this group of patients in order to confirm these conclusions.
|
pubmed:language |
ita
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:issn |
0026-4733
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
49
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
693-6
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading | |
pubmed:articleTitle |
[Continuous suture in laparotomy using an absorbable eyelet thread according to the Smead Jones technique].
|
pubmed:affiliation |
I Divisione di Chirurgia Generale, Ospedale Maria Vittoria, Torino.
|
pubmed:publicationType |
Journal Article,
English Abstract
|