rdf:type |
|
lifeskim:mentions |
|
pubmed:issue |
1
|
pubmed:dateCreated |
1977-1-3
|
pubmed:abstractText |
A modified haemagglutination inhibition test for rubella antibodies, using standardized freeze-dried reagents, was developed and compared with haemagglutination inhibition tests using fresh erythrocytes. This comparison was made in collaboration with six European laboratories. A total of 4205 serum samples were tested. The results show that: (1) Sensitivity and reliability of the modified test are good; (2) the modified test can be performed in polystyrene microtitration plates.
|
pubmed:commentsCorrections |
|
pubmed:language |
eng
|
pubmed:journal |
|
pubmed:citationSubset |
IM
|
pubmed:chemical |
|
pubmed:status |
MEDLINE
|
pubmed:month |
Aug
|
pubmed:issn |
0022-1724
|
pubmed:author |
|
pubmed:issnType |
Print
|
pubmed:volume |
77
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
31-42
|
pubmed:dateRevised |
2010-9-3
|
pubmed:meshHeading |
|
pubmed:year |
1976
|
pubmed:articleTitle |
A modified haemagglutination inhibition test for rubella antibodies, using standardized, freeze-dried reagents. Report of a comparative multi-centre trial.
|
pubmed:publicationType |
Journal Article,
Comparative Study
|