Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:7799981rdf:typepubmed:Citationlld:pubmed
pubmed-article:7799981lifeskim:mentionsumls-concept:C0026838lld:lifeskim
pubmed-article:7799981lifeskim:mentionsumls-concept:C0004609lld:lifeskim
pubmed-article:7799981lifeskim:mentionsumls-concept:C1704970lld:lifeskim
pubmed-article:7799981lifeskim:mentionsumls-concept:C0936012lld:lifeskim
pubmed-article:7799981pubmed:issue1lld:pubmed
pubmed-article:7799981pubmed:dateCreated1995-1-23lld:pubmed
pubmed-article:7799981pubmed:abstractTextIntrathecal baclofen dramatically improves severe spastic syndromes. This improvement is likely related to reduced excitability of alpha-motoneurons. To investigate the influence of baclofen upon the alpha-motoneuron, we analyzed F-waves before and after intrathecal baclofen bolus injection (usually 50 micrograms) as well as after administration of different, constantly delivered doses (60-200 micrograms/day). Intrathecal baclofen bolus decreased the maximum F-wave amplitude (Fp) from an initial value of 9% of the maximum M amplitude (Mmax) (= F/M-ratio) to 2.4% of the Mmax after 130-180 min, reduced the mean F-wave amplitude 60% within 150 min, and shortened the mean duration by 40-60% after 130-180 min. Constantly delivered baclofen of 100 micrograms/day reduced the F/M-ratio from 5% to 2%, the mean F-wave amplitude by 40-80%, and the F-wave mean duration by 40-80%. The minimum F-wave latency did not change after bolus or during steady state administration. The findings indicate that the F-wave mean and maximum amplitude as well as the mean duration are altered in a quantifiable manner following intrathecal baclofen application.lld:pubmed
pubmed-article:7799981pubmed:languageenglld:pubmed
pubmed-article:7799981pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:7799981pubmed:citationSubsetIMlld:pubmed
pubmed-article:7799981pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:7799981pubmed:statusMEDLINElld:pubmed
pubmed-article:7799981pubmed:monthJanlld:pubmed
pubmed-article:7799981pubmed:issn0148-639Xlld:pubmed
pubmed-article:7799981pubmed:authorpubmed-author:ConradBBlld:pubmed
pubmed-article:7799981pubmed:authorpubmed-author:DressnandtJJlld:pubmed
pubmed-article:7799981pubmed:authorpubmed-author:AuerCClld:pubmed
pubmed-article:7799981pubmed:issnTypePrintlld:pubmed
pubmed-article:7799981pubmed:volume18lld:pubmed
pubmed-article:7799981pubmed:ownerNLMlld:pubmed
pubmed-article:7799981pubmed:authorsCompleteYlld:pubmed
pubmed-article:7799981pubmed:pagination103-7lld:pubmed
pubmed-article:7799981pubmed:dateRevised2004-11-17lld:pubmed
pubmed-article:7799981pubmed:meshHeadingpubmed-meshheading:7799981-...lld:pubmed
pubmed-article:7799981pubmed:meshHeadingpubmed-meshheading:7799981-...lld:pubmed
pubmed-article:7799981pubmed:meshHeadingpubmed-meshheading:7799981-...lld:pubmed
pubmed-article:7799981pubmed:meshHeadingpubmed-meshheading:7799981-...lld:pubmed
pubmed-article:7799981pubmed:meshHeadingpubmed-meshheading:7799981-...lld:pubmed
pubmed-article:7799981pubmed:meshHeadingpubmed-meshheading:7799981-...lld:pubmed
pubmed-article:7799981pubmed:meshHeadingpubmed-meshheading:7799981-...lld:pubmed
pubmed-article:7799981pubmed:meshHeadingpubmed-meshheading:7799981-...lld:pubmed
pubmed-article:7799981pubmed:year1995lld:pubmed
pubmed-article:7799981pubmed:articleTitleInfluence of baclofen upon the alpha-motoneuron in spasticity by means of F-wave analysis.lld:pubmed
pubmed-article:7799981pubmed:affiliationNeurologic Department, Technical University, Munich, Germany.lld:pubmed
pubmed-article:7799981pubmed:publicationTypeJournal Articlelld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:7799981lld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:7799981lld:pubmed