Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
15
pubmed:dateCreated
1995-6-9
pubmed:abstractText
The quantitative relation between ST-segment changes and the severity and extent of myocardial ischemia during coronary occlusion remains unclear. This study assesses whether ST-segment changes during percutaneous transluminal coronary angioplasty (PTCA) correlate with the amount of myocardium at risk, measured with technetium-99m hexakis 2-methoxyisobutyl isonitrile (MIBI; also called sestamibi) single-photon emission computed tomography (SPECT). Quantitative continuous dynamic vectorcardiography was performed during PTCA of the left anterior descending coronary artery in 11 patients (mean age 64.3 years) without previous myocardial infarction. Change in the magnitude of the ST vector (STc-VM) was continuously recorded. A standardized protocol of balloon inflations was used and technetium-99m MIBI was injected intravenously at the onset of the third inflation. SPECT imaging was performed 60 minutes later and compared to a rest acquisition. SPECT was quantified by bull's-eye analysis using: (1) the change in the pathologic/normal area count ratio (delta P/N) as an index of the severity of ischemia; and (2) planimetered defect size during PTCA as an indicator of the size of the area at risk. The delta P/N from baseline to balloon occlusion (22 +/- 11%) was correlated, albeit loosely, to the maximum value of STc-VM (245 +/- 186 microV, r = 0.62, p < 0.05), but there was no correlation between the size of the scintigraphic defect and STc-VM. Likewise, the sum of ST-segment elevation was correlated to delta P/N (r = 0.72, p < 0.02), but not to the size of the scintigraphic defect.(ABSTRACT TRUNCATED AT 250 WORDS)
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
AIM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
May
pubmed:issn
0002-9149
pubmed:author
pubmed:issnType
Print
pubmed:day
15
pubmed:volume
75
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
998-1002
pubmed:dateRevised
2010-11-18
pubmed:meshHeading
pubmed:year
1995
pubmed:articleTitle
Comparison using dynamic vectorcardiography and MIBI SPECT of ST-segment changes and myocardial MIBI uptake during percutaneous transluminal coronary angioplasty of the left anterior descending coronary artery.
pubmed:affiliation
Service de Cardiologie, Hôpital Bichat, Paris, France.
pubmed:publicationType
Journal Article, Comparative Study