Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
3
|
pubmed:dateCreated |
1995-6-9
|
pubmed:abstractText |
An enzyme immuno assay kit has been developed to detect anti-HIV antibody in urine. In order to examine the clinical utility of the kit, 1333 urine samples were assayed. These samples consisted of 233 urine samples from HIV infected patients, 472 samples from HIV uninfected patients including 203 samples from patients with urogenital diseases, and 628 samples from normal subjects. Anti-HIV antibodies were detected in all the urine samples from HIV infected patients, and the diagnostic sensitivity for HIV infection was 100% with no false negative cases. A variety of anti-HIV antibody titers were found in the urine samples from HIV infected patients. However, no significant differences were found in the distribution patterns of urinary anti-HIV antibody titers among AC, ARC and AIDS patients. False positives were determined in only five samples in 628 healthy subjects (0.8%), one in 19 patients with hepatitis (5.3%), one in 45 patients with hemophilia (2.2%) and two in 105 pregnant women (1.9%). The antibody titers of all the false positive samples in these groups were less than the cut-off index multiplied by two. However, relatively high positive rates were demonstrated in the samples from urogenital diseases (11.8%), diabetes mellitus (20.0%) and auto-immune diseases (7.3%). False positive results were found to be directly correlated to the protein concentration of urinary protein, especially the immunoglobulin concentration in urine. The assay system was also evaluated by various reproducibility tests performed by different operators at different laboratories. The test results were satisfactory.(ABSTRACT TRUNCATED AT 250 WORDS)
|
pubmed:language |
jpn
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Mar
|
pubmed:issn |
0047-1860
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
43
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
249-56
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:7745830-Female,
pubmed-meshheading:7745830-HIV Antibodies,
pubmed-meshheading:7745830-HIV Infections,
pubmed-meshheading:7745830-Humans,
pubmed-meshheading:7745830-Immunoenzyme Techniques,
pubmed-meshheading:7745830-Japan,
pubmed-meshheading:7745830-Male,
pubmed-meshheading:7745830-Predictive Value of Tests,
pubmed-meshheading:7745830-Pregnancy,
pubmed-meshheading:7745830-Pregnancy Complications, Infectious,
pubmed-meshheading:7745830-Reagent Kits, Diagnostic,
pubmed-meshheading:7745830-Reproducibility of Results,
pubmed-meshheading:7745830-Sensitivity and Specificity
|
pubmed:year |
1995
|
pubmed:articleTitle |
[Clinical usefulness of urinary anti HIV antibody test--a large scale study from 11 institutes in Japan].
|
pubmed:affiliation |
AIDS Research Center, National Institute of Health, Shinjuku-ku, Tokyo.
|
pubmed:publicationType |
Journal Article,
Clinical Trial,
English Abstract,
Multicenter Study
|