pubmed:abstractText |
A widely used immunoglobulin M (IgM) detection assay for the diagnosis of neonatal congenital syphilis is the fluorescent treponemal antibody absorption test used with fractionated serum (FTA-ABS 19S IgM test). Reading the results of the FTA-ABS test is more cumbersome than reading those of the FTA-ABS double staining (FTA-ABS-DS) test, a confirmatory test for specific IgG. To verify that the FTA-ABS-DS test used with an anti-human IgM conjugate could detect specific IgM in fractionated serum samples (FTA-ABS-DS 19S IgM test), 164 fractionated (QUIK-SEP IgM Isolation System; ISOLAB, Inc., Akron, Ohio) serum specimens from infected neonates or adults or from IgG-seronegative subjects were tested by both techniques. The sensitivity limits of the two tests were assessed with reactive serum samples diluted to an endpoint titer. Samples nonreactive by the FTA-ABS 19S IgM test (n = 74) were either nonreactive (n = 65), minimally reactive (n = 5), or reactive (n = 4) by the FTA-ABS-DS 19S IgM test. Samples minimally reactive by the FTA-ABS 19S IgM test (n = 32) were minimally reactive (n = 1) or reactive (n = 31) by the double staining test. All samples reactive by the FTA-ABS 19S IgM test (n = 58) were also reactive by the FTA-ABS-DS 19S IgM test. There was a directly proportional linear relationship (r = 0.9794) between titers obtained by both tests. FTA-ABS-DS 19S IgM titers were constantly equal to or higher than FTA-ABS 19S IgM titers. Fluorescence intensity reading repeatability was 91.4% for the FTA-ABS-DS 19S IgM test and 81.7% for the FTA-ABS 19S IgM test (P = 0.015). Because the more easily read FTA-ABS-DS 19S IgM test is at least as sensitive as, if not more sensitive than, the FTA-ABS 19S IgM test, it is a good alternative to the latter test for the detection of specific IgM in human fractionated sera for those using fluorescence microscopes with incident light.
|
pubmed:commentsCorrections |
http://linkedlifedata.com/resource/pubmed/commentcorrection/7678016-14153657,
http://linkedlifedata.com/resource/pubmed/commentcorrection/7678016-2179261,
http://linkedlifedata.com/resource/pubmed/commentcorrection/7678016-2671033,
http://linkedlifedata.com/resource/pubmed/commentcorrection/7678016-2676323,
http://linkedlifedata.com/resource/pubmed/commentcorrection/7678016-3544254,
http://linkedlifedata.com/resource/pubmed/commentcorrection/7678016-6417160
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Jan
|
pubmed:issn |
0095-1137
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
31
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
102-6
|
pubmed:dateRevised |
2009-11-18
|
pubmed:meshHeading |
pubmed-meshheading:7678016-Adult,
pubmed-meshheading:7678016-Chi-Square Distribution,
pubmed-meshheading:7678016-Fluorescent Treponemal Antibody-Absorption Test,
pubmed-meshheading:7678016-Humans,
pubmed-meshheading:7678016-Immunoglobulin M,
pubmed-meshheading:7678016-Infant, Newborn,
pubmed-meshheading:7678016-Reproducibility of Results,
pubmed-meshheading:7678016-Sensitivity and Specificity,
pubmed-meshheading:7678016-Staining and Labeling,
pubmed-meshheading:7678016-Syphilis,
pubmed-meshheading:7678016-Syphilis, Congenital,
pubmed-meshheading:7678016-Treponema pallidum
|
pubmed:year |
1993
|
pubmed:articleTitle |
Comparison of the fluorescent treponemal antibody absorption (FTA-ABS) test with the FTA-ABS double staining test for detection of antitreponemal immunoglobulin M in the 19S fraction of human serum.
|
pubmed:affiliation |
Laboratoire de Santé Publique du Québec, Ste-Anne-de-Bellevue, Canada.
|
pubmed:publicationType |
Journal Article,
Comparative Study
|