Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
6
pubmed:dateCreated
1995-10-2
pubmed:abstractText
Seven patients with infected transvenous dual chambered pacemakers have undergone removal of the device using cardiopulmonary bypass. There were four women and three men with a mean age of 58 years. Six patients had localized infection in the generator pocket (mean of 4.6 previous unsuccessful operations for surgical sterilization). Four infections were due to Staphylococcus epidermidis, two to Staphylococcus aureus, and one patient presented septicemia caused by Staphylococcus epidermidis and Pseudomonas aeruginosa. The atrial and ventricular transvenous electrodes were removed under direct vision using cardiopulmonary bypass. A new dual chambered epicardial pacemaker was implanted. The procedure was well-tolerated, and all patients are infection free with working pacemakers after a mean follow-up of 25.4 months.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:month
Jun
pubmed:issn
0147-8389
pubmed:author
pubmed:issnType
Print
pubmed:volume
18
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
1272-5
pubmed:dateRevised
2004-11-17
pubmed:meshHeading
pubmed:year
1995
pubmed:articleTitle
Removal of infected dual chambered transvenous pacemaker and implantation of a new epicardial dual chambered device with cardiopulmonary bypass: experience with seven cases.
pubmed:affiliation
Department of Cardio-Vascular Surgery, Hospital NS del Pino, Las Palmas Gran Canaria, Spain.
pubmed:publicationType
Journal Article