Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:7651994rdf:typepubmed:Citationlld:pubmed
pubmed-article:7651994lifeskim:mentionsumls-concept:C0035868lld:lifeskim
pubmed-article:7651994lifeskim:mentionsumls-concept:C0012727lld:lifeskim
pubmed-article:7651994lifeskim:mentionsumls-concept:C0040399lld:lifeskim
pubmed-article:7651994lifeskim:mentionsumls-concept:C0002045lld:lifeskim
pubmed-article:7651994lifeskim:mentionsumls-concept:C0205099lld:lifeskim
pubmed-article:7651994pubmed:issue1lld:pubmed
pubmed-article:7651994pubmed:dateCreated1995-9-28lld:pubmed
pubmed-article:7651994pubmed:abstractTextIn this paper the importance of correcting a small centre-of-rotation displacement (approximately 1 mm) in single-photon-emission computed tomography (SPECT) using high-resolution pinhole collimation is demonstrated. A filtered backprojection (FBP) algorithm is derived for a pinhole geometry that has a displaced centre-of-rotation. The centre-of-rotation displacement, or mechanical shift (MS), is the displacement of the midplane of the pinhole collimator from the rotation centre. It is characterized by two orthogonal components: the shift eta of the midplane of the pinhole collimator along the direction of the axis of rotation, and the distance tau between the midline of the pinhole collimator and the axis of rotation. This algorithm is fast and corrects the centre-of-rotation displacement directly by incorporating this displacement into the algorithm. This new algorithm is evaluated using both a three-line source and a micro-SPECT cold rod phantom. The results demonstrate that the pinhole FBP with mechanical shift correction is able to correct the 'doughnut'-type artifacts caused by the mechanical shift and restore the expected system resolution.lld:pubmed
pubmed-article:7651994pubmed:granthttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:7651994pubmed:languageenglld:pubmed
pubmed-article:7651994pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:7651994pubmed:citationSubsetIMlld:pubmed
pubmed-article:7651994pubmed:statusMEDLINElld:pubmed
pubmed-article:7651994pubmed:monthJanlld:pubmed
pubmed-article:7651994pubmed:issn0031-9155lld:pubmed
pubmed-article:7651994pubmed:authorpubmed-author:ColemanR ERElld:pubmed
pubmed-article:7651994pubmed:authorpubmed-author:OOIS KSKlld:pubmed
pubmed-article:7651994pubmed:authorpubmed-author:JaszczakR JRJlld:pubmed
pubmed-article:7651994pubmed:authorpubmed-author:GreerK LKLlld:pubmed
pubmed-article:7651994pubmed:issnTypePrintlld:pubmed
pubmed-article:7651994pubmed:volume39lld:pubmed
pubmed-article:7651994pubmed:ownerNLMlld:pubmed
pubmed-article:7651994pubmed:authorsCompleteYlld:pubmed
pubmed-article:7651994pubmed:pagination165-76lld:pubmed
pubmed-article:7651994pubmed:dateRevised2007-11-14lld:pubmed
pubmed-article:7651994pubmed:meshHeadingpubmed-meshheading:7651994-...lld:pubmed
pubmed-article:7651994pubmed:meshHeadingpubmed-meshheading:7651994-...lld:pubmed
pubmed-article:7651994pubmed:meshHeadingpubmed-meshheading:7651994-...lld:pubmed
pubmed-article:7651994pubmed:meshHeadingpubmed-meshheading:7651994-...lld:pubmed
pubmed-article:7651994pubmed:meshHeadingpubmed-meshheading:7651994-...lld:pubmed
pubmed-article:7651994pubmed:meshHeadingpubmed-meshheading:7651994-...lld:pubmed
pubmed-article:7651994pubmed:year1994lld:pubmed
pubmed-article:7651994pubmed:articleTitleA filtered backprojection algorithm for pinhole SPECT with a displaced centre of rotation.lld:pubmed
pubmed-article:7651994pubmed:affiliationDepartment of Radiology, Duke University Medical Center, Durham, NC 27710, USA.lld:pubmed
pubmed-article:7651994pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:7651994pubmed:publicationTypeResearch Support, U.S. Gov't, P.H.S.lld:pubmed
pubmed-article:7651994pubmed:publicationTypeResearch Support, U.S. Gov't, Non-P.H.S.lld:pubmed