NMR microimages of single neural cells were acquired at 500 MHz using a conventional spin echo pulse sequence and a line-narrowing sequence that eliminates susceptibility effects. The data show that any contribution to the measured T2 relaxation rate arising from diffusion in local field inhomogeneities using spin echo sequences at high fields and high spatial resolution is relatively small. We conclude that the measured T2 difference between the nucleus and cytoplasm in these cells represents primarily a true T2 relaxation effect arising from the interactions of water with macromolecules in the two compartments and does not result from microsusceptibility differences. These observations have implications regarding water compartmentation in single cells and the interpretation of the MR characteristics of tissues in vivo.