pubmed:abstractText
The clinical performance of the Medtronic Intact porcine bioprosthesis was evaluated in 1,084 patients (mean age 66.4 years, range 9 to 91 years) who had a total of 1,099 implantations between 1985 and 1992, inclusive. There were 709 aortic valve replacements, 297 mitral valve replacements, and 80 multiple valve replacements. Concomitant procedures were performed in 432 (39.3%). The age group distribution (years) was 35 or younger in 20 patients, 36 to 50 in 64, 51 to 64 in 274, 65 to 69 in 225, 70 or older in 500. The total follow-up time was 2,741 patient-years (mean, 2.5 years) and was 97.5% complete. The early mortality rate was 7.1% and late mortality was 3.9% per patient-year. The overall patient survival at 7 years was 70% +/- 3%. The freedom from major thromboembolism was 94% +/- 1% at 7 years (p = not significant for valve positions). The freedom from reoperation at 7 years was 93% +/- 1%; freedom from valve-related mortality was 89% +/- 2%. The freedom from structural valve deterioration at 7 years was 97% +/- 1% (aortic valve replacement 97% +/- 1%; mitral valve replacement 97% +/- 2%). The freedom from structural valve deterioration among age groups was not different for the overall population, aortic valve replacement, or mitral valve replacement. Hemodynamic assessment revealed obstructive properties for aortic valve replacement sizes of 21 and 23 mm and for mitral valve replacement sizes of 25 and 27 mm.(ABSTRACT TRUNCATED AT 250 WORDS)
pubmed:commentsCorrections
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
AIM
pubmed:status
MEDLINE
pubmed:month
Aug
pubmed:issn
0003-4975
pubmed:author
pubmed:issnType
Print
pubmed:volume
60
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
S258-63
pubmed:dateRevised
2004-11-17
pubmed:meshHeading
pubmed-meshheading:7646169-Actuarial Analysis, pubmed-meshheading:7646169-Adolescent, pubmed-meshheading:7646169-Adult, pubmed-meshheading:7646169-Aged, pubmed-meshheading:7646169-Aged, 80 and over, pubmed-meshheading:7646169-Aortic Valve, pubmed-meshheading:7646169-Bioprosthesis, pubmed-meshheading:7646169-Child, pubmed-meshheading:7646169-Endocarditis, pubmed-meshheading:7646169-Female, pubmed-meshheading:7646169-Follow-Up Studies, pubmed-meshheading:7646169-Heart Valve Prosthesis, pubmed-meshheading:7646169-Humans, pubmed-meshheading:7646169-Male, pubmed-meshheading:7646169-Middle Aged, pubmed-meshheading:7646169-Mitral Valve, pubmed-meshheading:7646169-Postoperative Complications, pubmed-meshheading:7646169-Prosthesis Failure, pubmed-meshheading:7646169-Reoperation, pubmed-meshheading:7646169-Survival Rate, pubmed-meshheading:7646169-Thromboembolism
pubmed:year
1995
pubmed:articleTitle
Medtronic Intact porcine bioprosthesis: clinical performance to seven years.
pubmed:affiliation
Laval University, Quebec, Canada.
pubmed:publicationType
Journal Article