Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
3
pubmed:dateCreated
1982-6-21
pubmed:abstractText
Forty-six consecutive studies of carotid bifurcations were done with a Hokanson Ultrasonic Arteriograph before contrast arteriography. Based on the Doppler signal and the oscilloscopic image, each internal carotid artery was sorted into one of four categories as an estimation of the percent diameter reduction: less than or equal to 10 percent, 10 percent to 49 percent, 50 percent to 99 percent, and total occlusion. These results were compared with the percent diameter reduction determined from contrast arteriograms by a vascular radiologist unaware of the noninvasive test results. Overall, 83 percent of the arteries were correctly categorized. Detection of stenosis in the 50 percent to 99 percent range was 89 percent accurate. The sensitivity and specificity in detecting a 50 percent or greater stenosis were both 96 percent.
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/7340116-1006515, http://linkedlifedata.com/resource/pubmed/commentcorrection/7340116-103412, http://linkedlifedata.com/resource/pubmed/commentcorrection/7340116-461794, http://linkedlifedata.com/resource/pubmed/commentcorrection/7340116-4705956, http://linkedlifedata.com/resource/pubmed/commentcorrection/7340116-4815923, http://linkedlifedata.com/resource/pubmed/commentcorrection/7340116-496625, http://linkedlifedata.com/resource/pubmed/commentcorrection/7340116-5578847, http://linkedlifedata.com/resource/pubmed/commentcorrection/7340116-644444, http://linkedlifedata.com/resource/pubmed/commentcorrection/7340116-686896, http://linkedlifedata.com/resource/pubmed/commentcorrection/7340116-708257, http://linkedlifedata.com/resource/pubmed/commentcorrection/7340116-7191494, http://linkedlifedata.com/resource/pubmed/commentcorrection/7340116-7436733, http://linkedlifedata.com/resource/pubmed/commentcorrection/7340116-759935, http://linkedlifedata.com/resource/pubmed/commentcorrection/7340116-850872, http://linkedlifedata.com/resource/pubmed/commentcorrection/7340116-921536, http://linkedlifedata.com/resource/pubmed/commentcorrection/7340116-960001
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:month
Sep
pubmed:issn
0093-0415
pubmed:author
pubmed:issnType
Print
pubmed:volume
135
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
183-7
pubmed:dateRevised
2009-11-18
pubmed:meshHeading
pubmed:year
1981
pubmed:articleTitle
Ultrasonic arteriography: implications in patient management.
pubmed:publicationType
Journal Article, Comparative Study