Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
1
pubmed:dateCreated
1982-7-8
pubmed:abstractText
We compared the accuracy, precision, and between-method error of the microbiological assay, the radioenzymatic assay, the homogeneous enzyme immunoassay, and the high-performance liquid chromatographic assay for the quantitation of gentamicin in serum. Precision and accuracy were evaluated by reference samples prepared to contain 0.0 to 32.7 micrograms of gentamicin per ml. Correlations between the methods utilized patient sera with gentamicin concentrations ranging from 0.6 to 13.3 micrograms/ml. All methods were reliable within acceptable limits for routine clinical use; intermethod correlation coefficients exceeded 0.96. Relative to the microbiological assay, the alternative methods offer the advantage of rapid analysis. The elapsed times for acquiring data on a set of 10 specimens under routine operating conditions were 0.5 h by the enzyme immunoassay, 4 h by the radioenzymatic assay, 5 h by the high-performance liquid chromatographic assay, and 10 h by the microbiological assay.
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-1103724, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-1164007, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-17482, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-326439, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-369455, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-378464, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-411610, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-4361582, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-4598849, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-4683366, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-4791309, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-4799556, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-4842335, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-4999161, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-6991525, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-699279, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-6994639, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-709826, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-719861, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-732384, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-808583, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-848941, http://linkedlifedata.com/resource/pubmed/commentcorrection/7044297-902407
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Jan
pubmed:issn
0066-4804
pubmed:author
pubmed:issnType
Print
pubmed:volume
21
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
19-25
pubmed:dateRevised
2009-11-18
pubmed:meshHeading
pubmed:year
1982
pubmed:articleTitle
Performance characteristics of bioassay, radioenzymatic assay, homogeneous enzyme immunoassay, and high-performance liquid chromatographic determination of serum gentamicin.
pubmed:publicationType
Journal Article, Comparative Study