pubmed:abstractText |
An enzymatic method is described for the determination of total cholesterol in serum using a single aqueous reagent which can easily be prepared from commercial substrates and enzymes. The determination is carried out manually, the resulting stable chromogen is measured at a wavelength of 500-550 nm. The cholesterol concentration may be calculated either using a primary cholesterol standard or a constant factor for a given wavelength. The reliability of the method is reported: Data for the imprecision are given on the basis of a survey in 3 laboratories, the accuracy is established by comparison with a definitive and a reference method. Analytical and biological interferances are briefly discussed and results with this enzymatic method are reported concerning the reference values for serum cholesterol.
|
pubmed:language |
ger
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Jun
|
pubmed:issn |
0340-076X
|
pubmed:author |
pubmed-author:AssmannGG,
pubmed-author:BornerKK,
pubmed-author:EggsteinMM,
pubmed-author:GambertPP,
pubmed-author:HeuckC CCC,
pubmed-author:KattermannRR,
pubmed-author:KreutzF HFH,
pubmed-author:KupkeI RIR,
pubmed-author:SeidelDD,
pubmed-author:SiekmannLL,
pubmed-author:StammDD,
pubmed-author:WielandHH
|
pubmed:issnType |
Print
|
pubmed:volume |
21
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
347-55
|
pubmed:dateRevised |
2007-7-24
|
pubmed:meshHeading | |
pubmed:year |
1983
|
pubmed:articleTitle |
[Candidate selected method for the enzymatic determination of total cholesterol in serum].
|