pubmed:abstractText |
We compared two methods for quantitating antigen-specific antibody by a reverse enzyme-linked immunosorbent assay. In the serial-dilution method, the result was determined to be the highest dilution of a serum yielding an absorbance above an established threshold. In the single-dilution method, the result was determined by comparing the absorbance yielded by the test serum at a standard dilution to that yielded by positive and negative reference sera at the same dilution. The results in the single-dilution method reflected the antigen-specific immunoglobulin M antibody activity as a proportion of total immunoglobulin M antibody in a serum, i.e., the immune load, whereas the results in the serial-dilution method reflected the absolute concentration of antigen-specific immunoglobulin M antibody activity. Compared with results in the serial-dilution method, results in the single-dilution method had considerably greater reproducibility on a day-to-day basis and under various test conditions. The single-dilution method was more useful in discriminating between sera from patients in an early stage of clinical infection due to Toxoplasma gondii and sera from patients in a later stage of infection.
|
pubmed:grant | |
pubmed:commentsCorrections |
http://linkedlifedata.com/resource/pubmed/commentcorrection/6885993-231096,
http://linkedlifedata.com/resource/pubmed/commentcorrection/6885993-395275,
http://linkedlifedata.com/resource/pubmed/commentcorrection/6885993-5135623,
http://linkedlifedata.com/resource/pubmed/commentcorrection/6885993-6154109,
http://linkedlifedata.com/resource/pubmed/commentcorrection/6885993-6172520,
http://linkedlifedata.com/resource/pubmed/commentcorrection/6885993-6270191,
http://linkedlifedata.com/resource/pubmed/commentcorrection/6885993-7000834,
http://linkedlifedata.com/resource/pubmed/commentcorrection/6885993-7007520,
http://linkedlifedata.com/resource/pubmed/commentcorrection/6885993-7021589,
http://linkedlifedata.com/resource/pubmed/commentcorrection/6885993-7077100,
http://linkedlifedata.com/resource/pubmed/commentcorrection/6885993-7452400,
http://linkedlifedata.com/resource/pubmed/commentcorrection/6885993-80616
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Jul
|
pubmed:issn |
0095-1137
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
18
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
63-70
|
pubmed:dateRevised |
2010-9-10
|
pubmed:meshHeading |
pubmed-meshheading:6885993-Antibody Specificity,
pubmed-meshheading:6885993-Calibration,
pubmed-meshheading:6885993-Enzyme-Linked Immunosorbent Assay,
pubmed-meshheading:6885993-Humans,
pubmed-meshheading:6885993-Immunoglobulin M,
pubmed-meshheading:6885993-Toxoplasma,
pubmed-meshheading:6885993-Toxoplasmosis
|
pubmed:year |
1983
|
pubmed:articleTitle |
Comparison of methods for quantitating antigen-specific immunoglobulin M antibody with a reverse enzyme-linked immunosorbent assay.
|
pubmed:publicationType |
Journal Article,
Comparative Study,
Research Support, U.S. Gov't, P.H.S.,
Research Support, Non-U.S. Gov't
|