pubmed:abstractText |
One hundred and seventy one eyes with intraocular lenses were studied to compare the predictive accuracy of the Fyodorov and Van der Heijde theoretical formulae of the Sanders-Retzlaff-Kraff (SRK) regression formula. The SRK regression formula was the most accurate. Our personal calculations of the A constants of this formula are given for several types of implants and manufacturers.
|
pubmed:commentsCorrections |
|
pubmed:language |
eng
|
pubmed:journal |
|
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Apr
|
pubmed:issn |
0007-1161
|
pubmed:author |
|
pubmed:issnType |
Print
|
pubmed:volume |
68
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
235-7
|
pubmed:dateRevised |
2009-11-18
|
pubmed:meshHeading |
|
pubmed:year |
1984
|
pubmed:articleTitle |
The SRK regression formula in calculating the dioptric power of intraocular lenses.
|
pubmed:publicationType |
Journal Article,
Comparative Study
|