Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
4
|
pubmed:dateCreated |
1984-3-7
|
pubmed:abstractText |
To define normal criteria of size and dynamics of the inferior vena cava (IVC) and its clinical value in assessing right-sided cardiac function, 2-dimensional (2-D) and M-mode echocardiography (echo) were performed in 175 subjects, who were classified into 3 groups: group 1-80 normal subjects; group IIA--65 patients with documented right-sided cardiac disease, and group IIB--30 patients with cardiac disease but no right-sided abnormality. The IVC was adequately imaged in 175 of 185 subjects (95%). There was good correlation between M-mode and 2-D echo (r = 0.84) and long- and short-axis (r = 0.88) measurements. The IVC diameter during expiration was: group 1-9 to 28 mm (mean 18.2 +/- 4.6); group IIA--15 to 40 mm (mean 23.1 +/- 4.8) and group IIB-8-24 mm (mean 15.6 +/- 3.7). Collapsibility index (inspiratory decrease in diameter) was: group I-37 to 100% (mean 55.8 +/- 15.9); group IIA--0 to 39% (mean 13.5 +/- 10.5); and group IIB--44 to 100% (mean 60.4 +/- 13.1). A and V waves could be measured in 120 of 151 cases (79%). Both A and V waves were less than 125% of its diameter in group I. The A wave was absent in 34 patients; 30 (88%) were in atrial fibrillation. Among 8 patients with tricuspid regurgitation, 5 (63%) had V waves greater than 125%. There was no correlation between diameter or collapsibility index and age, sex, rhythm or body surface area.(ABSTRACT TRUNCATED AT 250 WORDS)
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
AIM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Feb
|
pubmed:issn |
0002-9149
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:day |
1
|
pubmed:volume |
53
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
579-85
|
pubmed:dateRevised |
2004-11-17
|
pubmed:meshHeading |
pubmed-meshheading:6695787-Adolescent,
pubmed-meshheading:6695787-Adult,
pubmed-meshheading:6695787-Aged,
pubmed-meshheading:6695787-Blood Pressure,
pubmed-meshheading:6695787-Compliance,
pubmed-meshheading:6695787-Echocardiography,
pubmed-meshheading:6695787-Female,
pubmed-meshheading:6695787-Heart,
pubmed-meshheading:6695787-Heart Atria,
pubmed-meshheading:6695787-Heart Diseases,
pubmed-meshheading:6695787-Humans,
pubmed-meshheading:6695787-Male,
pubmed-meshheading:6695787-Middle Aged,
pubmed-meshheading:6695787-Respiration,
pubmed-meshheading:6695787-Vasomotor System,
pubmed-meshheading:6695787-Vena Cava, Inferior
|
pubmed:year |
1984
|
pubmed:articleTitle |
Evaluation of size and dynamics of the inferior vena cava as an index of right-sided cardiac function.
|
pubmed:publicationType |
Journal Article
|