Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
4
pubmed:dateCreated
1984-4-25
pubmed:abstractText
Blood haemoglobin and serum ferritin levels were measured at the initial visit and 12 months following sterilization and IUD insertion. Ferritin levels were unaltered in Progestasert users after 12 months but haemoglobin values increased though not significantly. Ferritin levels fell in Multiload Cu 250 users and in sterilized women; haemoglobin levels were also observed to fall but significantly only in the latter group. Iron-deficiency anaemia was prevalent at initial contact and there appeared to be an increased risk subsequently in Multiload Cu 250 users and in those who were sterilized. Screening and monitoring for anaemia is indicated. From the viewpoint of iron status, the Progestasert is preferable to the Multiload Cu 250 but it suffers the major disadvantages of needing frequent replacement and of causing menstrual disturbances which might compromise its acceptability. Menstrual blood loss studies may help explain why anaemia develops after sterilization.
pubmed:keyword
http://linkedlifedata.com/resource/pubmed/keyword/Asia, http://linkedlifedata.com/resource/pubmed/keyword/Biology, http://linkedlifedata.com/resource/pubmed/keyword/COPPER, http://linkedlifedata.com/resource/pubmed/keyword/Contraception, http://linkedlifedata.com/resource/pubmed/keyword/Contraceptive Methods, http://linkedlifedata.com/resource/pubmed/keyword/Developing Countries, http://linkedlifedata.com/resource/pubmed/keyword/Endoscopy, http://linkedlifedata.com/resource/pubmed/keyword/Examinations And Diagnoses, http://linkedlifedata.com/resource/pubmed/keyword/Family Planning, http://linkedlifedata.com/resource/pubmed/keyword/Female Sterilization, http://linkedlifedata.com/resource/pubmed/keyword/Gynecologic Surgery, http://linkedlifedata.com/resource/pubmed/keyword/Hematological Effects, http://linkedlifedata.com/resource/pubmed/keyword/Hemic System, http://linkedlifedata.com/resource/pubmed/keyword/Hemoglobin Level--analysis, http://linkedlifedata.com/resource/pubmed/keyword/Ingredients And Chemicals, http://linkedlifedata.com/resource/pubmed/keyword/Inorganic Chemicals, http://linkedlifedata.com/resource/pubmed/keyword/Insertion, http://linkedlifedata.com/resource/pubmed/keyword/Iud, http://linkedlifedata.com/resource/pubmed/keyword/Iud, Copper Releasing, http://linkedlifedata.com/resource/pubmed/keyword/Iud, Hormone Releasing, http://linkedlifedata.com/resource/pubmed/keyword/LAPAROSCOPY, http://linkedlifedata.com/resource/pubmed/keyword/Laboratory Examinations And Diagnoses, http://linkedlifedata.com/resource/pubmed/keyword/Laboratory Procedures, http://linkedlifedata.com/resource/pubmed/keyword/MALAYSIA, http://linkedlifedata.com/resource/pubmed/keyword/METALS, http://linkedlifedata.com/resource/pubmed/keyword/Physical Examinations And Diagnoses, http://linkedlifedata.com/resource/pubmed/keyword/Physiology, http://linkedlifedata.com/resource/pubmed/keyword/Prospective Studies, http://linkedlifedata.com/resource/pubmed/keyword/Research Methodology, http://linkedlifedata.com/resource/pubmed/keyword/Serum Iron Level--analysis, http://linkedlifedata.com/resource/pubmed/keyword/Southeastern Asia, http://linkedlifedata.com/resource/pubmed/keyword/Sterilization, Sexual, http://linkedlifedata.com/resource/pubmed/keyword/Studies, http://linkedlifedata.com/resource/pubmed/keyword/Surgery, http://linkedlifedata.com/resource/pubmed/keyword/Treatment, http://linkedlifedata.com/resource/pubmed/keyword/Urogenital Surgery
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Oct
pubmed:issn
0010-7824
pubmed:author
pubmed:issnType
Print
pubmed:volume
28
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
329-36
pubmed:dateRevised
2006-11-15
pubmed:otherAbstract
PIP: Blood hemoglobin and serum ferritin levels were measured at the initial visit and 12 months after sterilization and IUD insertion. Ferritin levels were unaltered in Progestasert users after 12 months but hemoglobin values increased though not significantly. Ferritin levels fell in Multiload Cu250 users and in sterilized women; hemoglobin levels were also observed to fall but were significant only in the latter group. Iron deficiency anemia was prevalent at initial contact and there appeared to be an increased risk subsequently in Multiload Cu250 users and in those who were sterilized. Screening and monitoring for anemia is indicated. From the viewpoint of iron status, the Progestasert is preferable to the Multiload Cu250 but it has the major disadvantages of needing frequent replacement and of causing menstrual disturbances which might compromise its acceptability. Menstrual blood loss studies may help explain why anemia develops after sterilization.
pubmed:meshHeading
pubmed:year
1983
pubmed:articleTitle
Effect of laparoscopic sterilization and insertion of Multiload Cu 250 and Progestasert IUDs on serum ferritin levels.
pubmed:publicationType
Journal Article, Clinical Trial, Comparative Study, Randomized Controlled Trial, Research Support, Non-U.S. Gov't