pubmed:abstractText |
Haemodynamic data were obtained during haemodialysis on 21 occasions in 7 patients with septicaemia and pancreatitis, and in 5 patients with primary renal failure without septicaemia or pancreatitis. In the former group of patients there was a lowering of the blood pressure 30, 60, 90 and 120 minutes after haemodialysis had been initiated, which was significantly greater than in the later group. The drop in the blood pressure was caused by a decreased cardiac output. The pulmonary wedge pressure dropped in all patients. Peripheral resistance and heart rate did not change during the whole procedure.
|
pubmed:language |
ger
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
May
|
pubmed:issn |
0043-5325
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:day |
25
|
pubmed:volume |
96
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
419-23
|
pubmed:dateRevised |
2007-11-15
|
pubmed:meshHeading |
pubmed-meshheading:6475065-Adult,
pubmed-meshheading:6475065-Aged,
pubmed-meshheading:6475065-Blood Pressure,
pubmed-meshheading:6475065-Cardiac Output,
pubmed-meshheading:6475065-Female,
pubmed-meshheading:6475065-Heart Rate,
pubmed-meshheading:6475065-Hemodynamics,
pubmed-meshheading:6475065-Humans,
pubmed-meshheading:6475065-Kidney Failure, Chronic,
pubmed-meshheading:6475065-Male,
pubmed-meshheading:6475065-Middle Aged,
pubmed-meshheading:6475065-Pancreatitis,
pubmed-meshheading:6475065-Renal Dialysis,
pubmed-meshheading:6475065-Sepsis
|
pubmed:year |
1984
|
pubmed:articleTitle |
[Circulatory behavior in critically ill patients during hemodialysis].
|
pubmed:publicationType |
Journal Article,
English Abstract
|