pubmed:abstractText
A 17-year-old girl had intraocular pressure readings of 30 to 40 mm Hg in both eyes, with normal visual fields and optic nerve heads. Medical treatment was unsuccessful in lowering the IOP measurements substantially. The central corneal thickness was 0.90 mm in each eye in the absence of corneal edema. Cannulation of the left anterior chamber revealed an IOP of 11 mm Hg, while the Perkins' and Schi?tz' tonometers gave readings of 35 and 34 mm Hg, respectively. Previously, elevated tonometry readings had been obtained by Goldmann's, Perkins', Schi?tz', MacKay and Marg's, pneumatic tonometer and air puff tonometer. This suggested that measurement of central corneal thickness be performed in cases in which IOP recordings do not correspond to other clinical findings.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
AIM
pubmed:status
MEDLINE
pubmed:month
Apr
pubmed:issn
0003-9950
pubmed:author
pubmed:issnType
Print
pubmed:volume
96
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
664-5
pubmed:dateRevised
2006-11-15
pubmed:meshHeading
pubmed:year
1978
pubmed:articleTitle
Increased corneal thickness simulating elevated intraocular pressure.