Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
3
|
pubmed:dateCreated |
1983-4-21
|
pubmed:abstractText |
The study was undertaken to validate phantom-derived corrections for errors in collimation due to septal penetration or scatter, which vary with the size of the gastric region of interest (ROI). Six volunteers received 495 ml of 20% glucose labeled with both In-113m DTPA and Tc-99m DTPA. Gastric emptying of each nuclide was monitored by gamma camera as well as by periodic removal and reinstillation of the meal through a gastric tube. Serial aspirates from the gastric tube confirmed parallel emptying of In-113m and Tc-99m, but analyses of gamma-camera data yielded parallel emptying only when adequate corrections were made for errors in collimation. Analyses of ratios of gastric counts from anterior to posterior, as well as analyses of peak-to-scatter ratios, revealed only small, insignificant anteroposterior movement of the tracers within the stomach during emptying. Accordingly, there was no significant improvement in the camera data when corrections were made for attenuation with intragastric depth.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical |
http://linkedlifedata.com/resource/pubmed/chemical/Indium,
http://linkedlifedata.com/resource/pubmed/chemical/Pentetic Acid,
http://linkedlifedata.com/resource/pubmed/chemical/Radioisotopes,
http://linkedlifedata.com/resource/pubmed/chemical/Technetium,
http://linkedlifedata.com/resource/pubmed/chemical/Technetium Tc 99m Pentetate
|
pubmed:status |
MEDLINE
|
pubmed:month |
Mar
|
pubmed:issn |
0161-5505
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
24
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
187-96
|
pubmed:dateRevised |
2007-11-15
|
pubmed:meshHeading |
pubmed-meshheading:6338170-Evaluation Studies as Topic,
pubmed-meshheading:6338170-Food,
pubmed-meshheading:6338170-Gastric Emptying,
pubmed-meshheading:6338170-Half-Life,
pubmed-meshheading:6338170-Humans,
pubmed-meshheading:6338170-Indium,
pubmed-meshheading:6338170-Mathematics,
pubmed-meshheading:6338170-Models, Structural,
pubmed-meshheading:6338170-Pentetic Acid,
pubmed-meshheading:6338170-Radioisotopes,
pubmed-meshheading:6338170-Technetium,
pubmed-meshheading:6338170-Technetium Tc 99m Pentetate
|
pubmed:year |
1983
|
pubmed:articleTitle |
Validation of corrections for errors in collimation during measurement of gastric emptying of nuclide-labeled meals.
|
pubmed:publicationType |
Journal Article,
Research Support, U.S. Gov't, Non-P.H.S.
|