Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
6099
pubmed:dateCreated
1978-2-18
pubmed:abstractText
A prospective study of the energy required for transthoracic ventricular defibrillation in adults showed that in 42 (81%) out of 52 episodes of ventricular fibrillation shocks of 100 watt-seconds (Ws) of stored energy were successful. Out of 233 episodes, 222 (95%) were converted by 200 W s shocks. Among patients in whom primary ventricular fibrillation occurred within one hour of the onset of acute myocardial infarction, 200 W s shocks were successful in 40 (98%) out of 41 episodes. When low-energy shocks failed, a stored energy of 400 W s invariably succeeded. The need for large and expensive defibrillators that store more than 400 W s and are less readily available is therefore questioned.
pubmed:commentsCorrections
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
AIM
pubmed:status
MEDLINE
pubmed:month
Nov
pubmed:issn
0007-1447
pubmed:author
pubmed:issnType
Print
pubmed:day
26
pubmed:volume
2
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
1379-81
pubmed:dateRevised
2009-11-18
pubmed:meshHeading
pubmed:year
1977
pubmed:articleTitle
Transthoracic ventricular defibrillation in adults.
pubmed:publicationType
Journal Article