pubmed:abstractText
Accurate dilution of a small blood volume with a carbon monoxide-saturated solution allows measurement of the whole blood O2 concentration as an increase in O2 tension in the solution. We have improved the method by simplifying both equipment and procedure. We also suggest an additional step in which the mixture is acidified, thereby allowing the measurement of CO2 concentration in the same solution with a CO2 electrode. The accuracy of both the O2 and CO2 determinations compares favorably with that obtained with other micromethods.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
May
pubmed:issn
0161-7567
pubmed:author
pubmed:issnType
Print
pubmed:volume
44
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
818-20
pubmed:dateRevised
2004-11-17
pubmed:meshHeading
pubmed:year
1978
pubmed:articleTitle
Measurement of blood O2 and CO2 concentrations using PO2 and PCO2 electrodes.