Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
2
pubmed:dateCreated
1970-3-19
pubmed:abstractText
The osmotic swelling of intact erythrocytes in hypotonic solutions was measured using microhematocrit tubes, Van Allen tubes, and a calibrated Coulter counter. In agreement with earlier workers the intact cells did not behave as perfect osmometers, the cells swelling less than predicted by the Boyle-van't Hoff law. Erythrocyte ghosts were prepared from fresh intact erythrocytes by one-step hemolysis in 0.25% NaCl at an extremely dilute concentration of cells and the membranes were sealed at 37 degrees . The ghosts were mixed with NaCl solutions of different osmolarities and the MCV (mean cell volume) of the shrunken cells immediately monitored by a calibrated Coulter counter. It was found that the MCV values of the shrunken ghosts were accurately predicted by the Boyle-van't Hoff law. These results indicate that these erythrocyte ghosts behaved as perfect osmometers.
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/5413078-10976201, http://linkedlifedata.com/resource/pubmed/commentcorrection/5413078-13816571, http://linkedlifedata.com/resource/pubmed/commentcorrection/5413078-13999462, http://linkedlifedata.com/resource/pubmed/commentcorrection/5413078-14028302, http://linkedlifedata.com/resource/pubmed/commentcorrection/5413078-14130437, http://linkedlifedata.com/resource/pubmed/commentcorrection/5413078-14212152, http://linkedlifedata.com/resource/pubmed/commentcorrection/5413078-14402408, http://linkedlifedata.com/resource/pubmed/commentcorrection/5413078-4225778, http://linkedlifedata.com/resource/pubmed/commentcorrection/5413078-4898480, http://linkedlifedata.com/resource/pubmed/commentcorrection/5413078-4972779, http://linkedlifedata.com/resource/pubmed/commentcorrection/5413078-5688085, http://linkedlifedata.com/resource/pubmed/commentcorrection/5413078-5710060, http://linkedlifedata.com/resource/pubmed/commentcorrection/5413078-5822820, http://linkedlifedata.com/resource/pubmed/commentcorrection/5413078-5822821, http://linkedlifedata.com/resource/pubmed/commentcorrection/5413078-5822822, http://linkedlifedata.com/resource/pubmed/commentcorrection/5413078-5822823, http://linkedlifedata.com/resource/pubmed/commentcorrection/5413078-5967694, http://linkedlifedata.com/resource/pubmed/commentcorrection/5413078-6033588
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Feb
pubmed:issn
0022-1295
pubmed:author
pubmed:issnType
Print
pubmed:volume
55
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
208-19
pubmed:dateRevised
2010-6-22
pubmed:meshHeading
pubmed:year
1970
pubmed:articleTitle
The erythrocyte ghost is a perfect osmometer.
pubmed:publicationType