Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
4 Pt 2
|
pubmed:dateCreated |
1986-5-13
|
pubmed:abstractText |
Pulsus alternans has previously been ascribed to variations in end-diastolic fiber length and/or an alternating contractile state. In six paced, whole blood-perfused, intact, working pig hearts, left ventricular internal diameters were measured with ultrasonic crystals, and left ventricular pressures were measured with a micromanometer-tipped catheter. Pulsus alternans was induced with propranolol (24-51 micrograms X kg-1 X min-1). End-systolic pressure-diameter relationships were determined during pulsus alternans from a series of consecutive, variably volume-loaded beats using a previously described technique. Beats analyzed prior to any change in loading conditions revealed a left ventricular pressure of 62.7 +/- 8.7 mmHg for the strong beats and 55.2 +/- 7.0 for the weak beats (P less than 0.050). The end-diastolic diameter prior to the stronger beats was larger than that prior to the weaker beats (24.80 +/- 2.73 vs. 23.82 +/- 2.82 mm, P less than 0.025), but there was no significant difference in the corresponding end-diastolic pressures. The maximum dP/dt of the strong beats was 1,275 +/- 249 mmHg/s compared with 1,038 +/- 222 for the weak beats (P less than 0.025). The slope of the end-systolic pressure-diameter relationship, which provides an index of contractility independent of end-diastolic diameter, averaged 42.3 +/- 6.4 mmHg/mm for the strong beats and 24.4 +/- 6.8 for the weak beats (P less than 0.025). These data support an alternating contractile state as an independent mechanism for pulsus alternans in the intact animal.
|
pubmed:grant | |
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Apr
|
pubmed:issn |
0002-9513
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
250
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
H606-11
|
pubmed:dateRevised |
2007-11-15
|
pubmed:meshHeading |
pubmed-meshheading:3963216-Animals,
pubmed-meshheading:3963216-Blood Pressure,
pubmed-meshheading:3963216-Elasticity,
pubmed-meshheading:3963216-Female,
pubmed-meshheading:3963216-Heart,
pubmed-meshheading:3963216-Heart Ventricles,
pubmed-meshheading:3963216-Hemodynamics,
pubmed-meshheading:3963216-Male,
pubmed-meshheading:3963216-Myocardial Contraction,
pubmed-meshheading:3963216-Stroke Volume,
pubmed-meshheading:3963216-Systole
|
pubmed:year |
1986
|
pubmed:articleTitle |
End-systolic pressure-diameter relationships during pulsus alternans in intact pig hearts.
|
pubmed:publicationType |
Journal Article,
Research Support, U.S. Gov't, P.H.S.,
Research Support, Non-U.S. Gov't
|