Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
4
|
pubmed:dateCreated |
1986-9-17
|
pubmed:abstractText |
Measurements of variceal pressure with a noninvasive endoscopic pressure gauge and by direct variceal puncture were performed in 20 cirrhotic patients with portal hypertension in the course of the first session of therapeutic sclerotherapy following an episode of variceal bleeding. Endoscopic gauge measurements of the pressure of esophageal varices gave similar values (15.5 +/- 2.7 mm Hg) than measurements by variceal puncture (15.4 +/- 2.4 mm Hg; not statistically significant), and there was a highly significant linear correlation between both measurements (r = 0.9, p less than 0.001). Azygos blood flow, that was markedly increased in these patients (852 +/- 399 ml per min), was directly related to variceal pressure (r = 0.73, p less than 0.01). Variceal pressure was significantly lower than portal pressure (18.8 +/- 5.0 mm Hg) (p less than 0.05), indicating that measurements of variceal pressure cannot substitute measurements of portal pressure. The study demonstrates that the noninvasive endoscopic gauge technique allows an accurate estimation of variceal pressure in patients with portal hypertension. This technique may provide additional useful information in the evaluation of portal hypertension as well as on the mechanism of variceal bleeding.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:issn |
0270-9139
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
6
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
667-72
|
pubmed:dateRevised |
2008-11-21
|
pubmed:meshHeading |
pubmed-meshheading:3733001-Adult,
pubmed-meshheading:3733001-Aged,
pubmed-meshheading:3733001-Azygos Vein,
pubmed-meshheading:3733001-Blood Pressure,
pubmed-meshheading:3733001-Esophageal and Gastric Varices,
pubmed-meshheading:3733001-Esophagoscopes,
pubmed-meshheading:3733001-Esophagoscopy,
pubmed-meshheading:3733001-Female,
pubmed-meshheading:3733001-Fiber Optic Technology,
pubmed-meshheading:3733001-Hepatic Veins,
pubmed-meshheading:3733001-Humans,
pubmed-meshheading:3733001-Hypertension, Portal,
pubmed-meshheading:3733001-Liver Cirrhosis, Alcoholic,
pubmed-meshheading:3733001-Male,
pubmed-meshheading:3733001-Middle Aged,
pubmed-meshheading:3733001-Pressure,
pubmed-meshheading:3733001-Punctures,
pubmed-meshheading:3733001-Sclerosing Solutions,
pubmed-meshheading:3733001-Transducers, Pressure
|
pubmed:articleTitle |
Noninvasive measurement of the pressure of esophageal varices using an endoscopic gauge: comparison with measurements by variceal puncture in patients undergoing endoscopic sclerotherapy.
|
pubmed:publicationType |
Journal Article,
Comparative Study,
Research Support, Non-U.S. Gov't
|