pubmed:abstractText
A simple HPLC method for penbutolol and 4-hydroxypenbutolol assay has been developed. Plasma or serum (200 microliters) is vortex-mixed (30 s) with Tris solution (2 M, pH 10.6) containing an internal standard (50 microliters) and methyl t-butyl ether (200 microliters). After centrifugation, the extract (100 microliters) is analysed using an unmodified silica column (250 x 5 mm ID) and iso-octane-methanol-methyl t-butyl ether (55:25:20) containing ammonium perchlorate (10 mM, pH 5.7) as eluent and with fluorescence detection. No interference has been encountered and the limit of accurate measurement for both compounds is 5 micrograms/l.