pubmed:abstractText
Three monitors designed for self monitoring of blood glucose concentrations by diabetic patients were evaluated in a laboratory. All three assessments correlated positively with a laboratory reference method based on glucose oxidase. Coefficients of variation at all levels tested were less than 10% for each monitor. Stability of the colour development of each stick was assessed and the effects of changes in blood spot volume and incubation time were examined. Twelve ward nurses were each asked to measure two blood samples and the results obtained showed wide variability. Overall, our findings suggest that each of the three monitors tested is suitable for use in monitoring capillary blood glucose concentrations by those who are properly trained.
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/3366924-1000801, http://linkedlifedata.com/resource/pubmed/commentcorrection/3366924-1157305, http://linkedlifedata.com/resource/pubmed/commentcorrection/3366924-1256496, http://linkedlifedata.com/resource/pubmed/commentcorrection/3366924-262186, http://linkedlifedata.com/resource/pubmed/commentcorrection/3366924-3522075, http://linkedlifedata.com/resource/pubmed/commentcorrection/3366924-3532917, http://linkedlifedata.com/resource/pubmed/commentcorrection/3366924-3916092, http://linkedlifedata.com/resource/pubmed/commentcorrection/3366924-4005724, http://linkedlifedata.com/resource/pubmed/commentcorrection/3366924-4678682, http://linkedlifedata.com/resource/pubmed/commentcorrection/3366924-6754165, http://linkedlifedata.com/resource/pubmed/commentcorrection/3366924-6875021, http://linkedlifedata.com/resource/pubmed/commentcorrection/3366924-7212503, http://linkedlifedata.com/resource/pubmed/commentcorrection/3366924-759256
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
AIM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Apr
pubmed:issn
0021-9746
pubmed:author
pubmed:issnType
Print
pubmed:volume
41
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
397-402
pubmed:dateRevised
2009-11-18
pubmed:meshHeading
pubmed:year
1988
pubmed:articleTitle
Laboratory assessment of three reflectance meters designed for self monitoring of blood glucose concentrations.
pubmed:affiliation
Department of Clinical Chemistry, Royal Hallamshire Hospital, Sheffield.
pubmed:publicationType