pubmed:abstractText |
A technique is described which enables precise temporary interstitial volume implantation of brain tumors using a CT stereotaxic guidance system. This technique has the advantages of designing irregular isodose distributions during the preplanning stage. Although the preplanning stage can be time-consuming, this is performed while the patient is in the hospital room and CT scanner time, anesthesia time, and operating room time is minimized for individual patients.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Nov
|
pubmed:issn |
0360-3016
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
13
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
1753-60
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:3312130-Astrocytoma,
pubmed-meshheading:3312130-Brachytherapy,
pubmed-meshheading:3312130-Brain Neoplasms,
pubmed-meshheading:3312130-Glioma,
pubmed-meshheading:3312130-Humans,
pubmed-meshheading:3312130-Iodine Radioisotopes,
pubmed-meshheading:3312130-Radiotherapy Dosage,
pubmed-meshheading:3312130-Radiotherapy Planning, Computer-Assisted,
pubmed-meshheading:3312130-Stereotaxic Techniques,
pubmed-meshheading:3312130-Tomography, X-Ray Computed
|
pubmed:year |
1987
|
pubmed:articleTitle |
Improved precision of interstitial brain tumor irradiation using the BRW CT stereotaxic guidance system.
|