pubmed:abstractText
Postoperative astigmatism is one of the major limitations of penetrating keratoplasty. In an attempt to reduce postkeratoplasty astigmatism, we combined corneal-relaxing incisions with orthogonal compression sutures, guided by the intraoperative use of a ring keratometer. Eleven consecutive patients from a mixed referral population with functionally disabling astigmatism were studied. The average preoperative keratometric cylinder of 11.68 diopters was reduced by 7.95 (+/- 3.03 SD) diopters. Each patient's net keratometric cylinder was reduced. We believe that this technique is safer and more predictable than previously published techniques.
pubmed:grant
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
AIM
pubmed:status
MEDLINE
pubmed:month
Jul
pubmed:issn
0003-9950
pubmed:author
pubmed:issnType
Print
pubmed:volume
105
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
954-7
pubmed:dateRevised
2007-11-14
pubmed:meshHeading
pubmed:year
1987
pubmed:articleTitle
Refractive keratoplasty for disabling astigmatism after penetrating keratoplasty.