Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
2
|
pubmed:dateCreated |
1987-8-7
|
pubmed:abstractText |
Three methods for measurement of tissue plasminogen activator (t-PA) activity in plasma were compared with regard to linearity, precision and clinical applicability. Based on this comparison a new improved technique is described. The 3 methods differed in the way the influence of inhibitors in plasma was eliminated. In method A t-PA was measured in acidified plasma, in method B in euglobulin precipitate and in method C after adsorption of plasma on lysine-Sepharose. After addition of 15 IU/ml of t-PA to normal plasma the recovery with method A was 17.4 +/- 2.4 IU/ml, with method B 11.4 +/- 0.5 IU/ml and with method C 9.8 +/- 0.9 IU/ml. When tested on venous stasis plasma from 10 patients the 3 methods correlated well with a correlation coefficient of r = 0.97 - 0.99. Significantly higher values were found in acidified plasma (method A) as compared to the other methods. From this evaluation a method for determination of t-PA activity using acidification and internal standard to abolish the influence of inhibitors and poly-D-lysine as a stimulator was selected. The recovery with this method was 103.4 +/- 8.5% independent of PA inhibitor content in the plasma.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical |
http://linkedlifedata.com/resource/pubmed/chemical/Acids,
http://linkedlifedata.com/resource/pubmed/chemical/Sepharose,
http://linkedlifedata.com/resource/pubmed/chemical/Serum Globulins,
http://linkedlifedata.com/resource/pubmed/chemical/Tissue Plasminogen Activator,
http://linkedlifedata.com/resource/pubmed/chemical/lysine-sepharose
|
pubmed:status |
MEDLINE
|
pubmed:month |
Apr
|
pubmed:issn |
0049-3848
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:day |
15
|
pubmed:volume |
46
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
213-23
|
pubmed:dateRevised |
2009-11-19
|
pubmed:meshHeading |
pubmed-meshheading:3111001-Acids,
pubmed-meshheading:3111001-Adsorption,
pubmed-meshheading:3111001-Blood Chemical Analysis,
pubmed-meshheading:3111001-Chemical Precipitation,
pubmed-meshheading:3111001-Humans,
pubmed-meshheading:3111001-Sepharose,
pubmed-meshheading:3111001-Serum Globulins,
pubmed-meshheading:3111001-Tissue Plasminogen Activator
|
pubmed:year |
1987
|
pubmed:articleTitle |
Measurement of tissue plasminogen activator in plasma. A comparison of 3 methods and description of a new improved technique.
|
pubmed:publicationType |
Journal Article,
Comparative Study,
Research Support, Non-U.S. Gov't
|