pubmed:abstractText
A polymeric analogue femur in combination with a brittle-coating stress-analysis technique was used to compare the relative femoral surface-strain distributions for various hip prostheses. The influence of prosthesis design factors, such as the geometry and material, the effect of a collar, and surface texturing, were readily ascertained and in agreement with previous investigations using other techniques. The fixation failures observed with this laboratory test model were similar to those of published clinical findings.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:issn
0883-9344
pubmed:author
pubmed:issnType
Print
pubmed:volume
46
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
143-9
pubmed:dateRevised
2004-11-17
pubmed:meshHeading
pubmed:year
1986
pubmed:articleTitle
Analogue femurs for laboratory investigations of prosthesis stress distributions and fixation failures.
pubmed:publicationType