pubmed:abstractText |
Early and late modifications of stenosis geometry after stenting of coronary arteries were assessed. Morphologic changes were evaluated by quantitative coronary angiography (automated edge-detection) and theoretical pressure drop across the dilated and stented stenosis was calculated from the Poiseuille formula, with turbulent resistances assuming a coronary blood flow of 1 or 3 ml/s. Eleven patients (ages 41 to 69 years, mean 55) were studied before and after angioplasty, and immediately after stent implantation. The stented coronary artery was the left anterior descending artery in 9 patients and the left circumflex in 2. Following stent implantation, an additional increase in minimal luminal cross-sectional area of the dilated vessel was observed, suggesting that the self-expanding stainless-steel endoprosthesis used had a dilating function in addition to its stenting role. Repeat angiography in 6 patients 3 months after stent implantation showed a decrease in the minimal luminal cross-sectional area without a significant change in theoretic pressure decrease. This slight reduction in vessel caliber had no hemodynamically significant repercussions. Thus, stenting of coronary arteries following dilatation is a potentially valuable technique for preventing both abrupt closure and late reduction in lumen diameter.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
AIM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Mar
|
pubmed:issn |
0002-9149
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:day |
1
|
pubmed:volume |
61
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
546-53
|
pubmed:dateRevised |
2004-11-17
|
pubmed:meshHeading |
pubmed-meshheading:2964192-Adult,
pubmed-meshheading:2964192-Aged,
pubmed-meshheading:2964192-Angioplasty, Balloon,
pubmed-meshheading:2964192-Blood Vessel Prosthesis,
pubmed-meshheading:2964192-Coronary Angiography,
pubmed-meshheading:2964192-Coronary Circulation,
pubmed-meshheading:2964192-Coronary Disease,
pubmed-meshheading:2964192-Coronary Vessels,
pubmed-meshheading:2964192-Female,
pubmed-meshheading:2964192-Humans,
pubmed-meshheading:2964192-Male,
pubmed-meshheading:2964192-Middle Aged,
pubmed-meshheading:2964192-Prostheses and Implants,
pubmed-meshheading:2964192-Stainless Steel,
pubmed-meshheading:2964192-Time Factors,
pubmed-meshheading:2964192-Vascular Patency,
pubmed-meshheading:2964192-Vascular Resistance
|
pubmed:year |
1988
|
pubmed:articleTitle |
Early and late assessment of stenosis geometry after coronary arterial stenting.
|
pubmed:affiliation |
Department of Clinical and Experimental Cardiology, CHRU, Rangueil, Toulouse, France.
|
pubmed:publicationType |
Journal Article
|