Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
1
|
pubmed:dateCreated |
1989-5-11
|
pubmed:abstractText |
The occurrence of late complications in implanted cardiac prosthetic valves has emphasized the need for the development of an animal model in which these complications are reproducible. Sheep constitute an excellent model for chronical and pathological studies of prosthetic devices. In our experience, survival of sheep following implantation of prosthetic valves is closely related to postoperative serum colloid osmotic pressure (C.O.P.). The normal range as measured in 28 healthy sheep was 16.67 +/- 0.55 mm Hg. A protocol was developed to maintain the colloid hydrostatic pressure gradient (C.H.P.G.) as close as possible to the normal physiological range, and to delay the extubation until the C.O.P. was within this range, and the C.H.P.G. greater than 7 mm Hg. Using the above protocol, a new tri-leaflet polyurethane valve was inserted into eight, five to seven month old sheep in place of the mitral and tricuspidal valves. One hour after terminating the extacorporeal circuit, the C.O.P. was measured at 13.10 +/- 0.96; but within five to six hours, it rose to 17.1 +/- 1.1. During the same period, the C.H.P.G. increased from 3.02 +/- 0.96 to 7.6 +/- 0.50 mm Hg. The postoperative period was uneventful, and all animals survived. We have thus concluded that the routine measurement and monitoring of C.O.P. constitutes a guide of great clinical importance.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Jan
|
pubmed:issn |
0391-3988
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
12
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
47-50
|
pubmed:dateRevised |
2003-11-14
|
pubmed:meshHeading |
pubmed-meshheading:2925261-Animals,
pubmed-meshheading:2925261-Colloids,
pubmed-meshheading:2925261-Disease Models, Animal,
pubmed-meshheading:2925261-Heart Valve Prosthesis,
pubmed-meshheading:2925261-Hydrostatic Pressure,
pubmed-meshheading:2925261-Male,
pubmed-meshheading:2925261-Mitral Valve,
pubmed-meshheading:2925261-Osmotic Pressure,
pubmed-meshheading:2925261-Polyurethanes,
pubmed-meshheading:2925261-Pulmonary Edema,
pubmed-meshheading:2925261-Sheep,
pubmed-meshheading:2925261-Tricuspid Valve
|
pubmed:year |
1989
|
pubmed:articleTitle |
The effect of colloid osmotic pressure on the survival of sheep following cardiac surgery.
|
pubmed:affiliation |
Tel Aviv Medical Center, Ramat Aviv-Israel.
|
pubmed:publicationType |
Journal Article
|