pubmed:abstractText
A novel high-performance liquid chromatographic method for the determination of codeine, norcodeine and morphine in plasma and urine has been developed. The compounds were separated on a cyano column (15 cm x 4.6 mm, 5 microns particle size) using a mobile phase of acetonitrile-triethylamine-distilled water (4:0.1:95.9, v/v) pH 3.1 and then determined by fluorescence detection. Calibration curves in the range 5-200 ng/ml for plasma and 0.1-10 micrograms/ml for urine were linear and passed through the origin. The imprecision and inaccuracy of the assay were less than 10% and the limits of detection were 2 ng/ml for all three compounds in human plasma.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Jul
pubmed:issn
0021-9673
pubmed:author
pubmed:issnType
Print
pubmed:day
21
pubmed:volume
491
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
367-78
pubmed:dateRevised
2006-11-15
pubmed:meshHeading
pubmed:year
1989
pubmed:articleTitle
Simultaneous determination of codeine, norcodeine and morphine in biological fluids by high-performance liquid chromatography with fluorescence detection.
pubmed:affiliation
Department of Clinical and Experimental Pharmacology, University of Adelaide, Australia.
pubmed:publicationType
Journal Article, Research Support, Non-U.S. Gov't