Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
2
pubmed:dateCreated
1981-11-24
pubmed:abstractText
We have recorded membrane impedance and voltage noise in the pacemaker range of potentials (-70 to -59 mV) from spheroidal aggregates of 7-d embryonic chick ventricle cells made quiescent by exposure to tetrodotoxin in medium containing 4.5 mM K+. The input capacitance is proportional to aggregate volume and therefore to total membrane area. The specific membrane capacitance is 1.24 microF/cm2. The input resistance at constant potential is inversely proportional to aggregate volume and therefore to total membrane area. The specific membrane resistance in 18 k omega . cm2 at -70 mV and increases to 81 k omega . cm2 at -59 mV. The RC time constant is 22 ms at -70 mV and increases to 146 ms at -59 mV. The aggregate transmembrane small-signal impedance can be represented by a parallel RC circuit itself in parallel with an inductive branch consisting of a resistor (rL) and an inductor (L) in series. The time constant of the inductive branch (L/rL) is 340 ms, and is only weakly dependent on potential. Correlation functions of aggregate voltage noise and the impedance data were modeled by a population of channels with simple open-close kinetics. The time constant of a channel (tau s) derived from the noise analysis is 300 ms. The low frequency limit of the pacemaker current noise (SI[0]), derived from the voltage noise and impedance, increases from 10(-20) A2/Hz . cm2 at -67 mV to 10(-19) A2/Hz . cm2 at -61 mV.
pubmed:grant
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-1033292, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-1086902, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-1087643, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-1117281, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-1151828, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-1185607, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-1238398, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-12991237, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-13773012, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-262383, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-304052, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-436747, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-438769, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-4407444, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-4566209, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-4683099, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-4697746, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-5044577, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-5044583, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-5424376, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-5435782, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-5476811, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-5639799, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-5972158, http://linkedlifedata.com/resource/pubmed/commentcorrection/262547-68708
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:month
Nov
pubmed:issn
0006-3495
pubmed:author
pubmed:issnType
Print
pubmed:volume
28
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
169-84
pubmed:dateRevised
2009-11-18
pubmed:meshHeading
pubmed:year
1979
pubmed:articleTitle
Current noise parameters derived from voltage noise and impedance in embryonic heart cell aggregates.
pubmed:publicationType
Journal Article, Research Support, U.S. Gov't, P.H.S.