Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
9
pubmed:dateCreated
1990-3-27
pubmed:abstractText
In five adult monkeys, electromyograms (EMGs) were recorded from bipolar surface electrodes positioned over the superficial masseter and from bipolar fine-wire electrodes within both the superficial and deep masseter. Relative masseter force was estimated by measuring surface bone strain from the lateral aspect of the zygomatic arch using rosette strain gauges. Multiple step-wise regression procedures demonstrated that peak values of the averaged masseter EMG could often explain a considerable amount of the variation of peak relative masseter force during mastication, i.e. r2 values ranged from 0.23 to 0.96 for the various single-electrode models and R2 values ranged from 0.78 to 0.96 for the various multiple-electrode models. The r2 values for relative masseter force and EMG data from the surface electrodes ranged from 0.69 to 0.96, and, on average, EMG data from surface electrodes provided somewhat more information about overall relative muscle force than data from fine-wire electrodes. The R2 values for a two-electrode model, consisting of data from surface electrodes over the superficial masseter and fine-wire electrodes in the posterior portion of the deep masseter, ranged from 0.78 to 0.95. The latency between the averaged surface EMG and relative muscle force was determined and the data indicated that the surface EMG usually preceded muscle force. This latency tended to decrease gradually throughout the entire power stroke of mastication. At peak values, the surface EMG preceded muscle force by about 22 ms. Towards the end of the power stroke, i.e. the 25% of peak values during unloading, muscle force may actually precede the average EMG.
pubmed:grant
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
D
pubmed:status
MEDLINE
pubmed:issn
0003-9969
pubmed:author
pubmed:issnType
Print
pubmed:volume
34
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
713-22
pubmed:dateRevised
2007-11-14
pubmed:meshHeading
pubmed:year
1989
pubmed:articleTitle
The relationship between masseter force and masseter electromyogram during mastication in the monkey Macaca fascicularis.
pubmed:affiliation
Department of Biological Anthropology and Anatomy, Duke University Medical Center, Durham, NC 27710.
pubmed:publicationType
Journal Article, Research Support, U.S. Gov't, P.H.S., Research Support, U.S. Gov't, Non-P.H.S., Research Support, Non-U.S. Gov't