pubmed-article:2564058pubmed:abstractTextIn 434 operations for valvular heart disease, patients were randomised to receive Björk-Shiley, Edwards-Duromedics, or Medtronic-Hall mechanical prostheses. At a median follow-up time of 37.5 months there were no differences in hazard of death or non-embolic events. In the first six postoperative months the incidence of thromboembolism was about the same for the three valves. Subsequently, however, the incidence of thromboembolism for the Edwards-Duromedics valve was 3.9 times higher than for the Björk-Shiley valve, and for the Medtronic-Hall valve 2.6 times higher than for the Björk-Shiley valve.lld:pubmed
pubmed-article:2564058pubmed:languageenglld:pubmed
pubmed-article:2564058pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:2564058pubmed:citationSubsetAIMlld:pubmed
pubmed-article:2564058pubmed:statusMEDLINElld:pubmed
pubmed-article:2564058pubmed:monthMarlld:pubmed
pubmed-article:2564058pubmed:issn0140-6736lld:pubmed
pubmed-article:2564058pubmed:authorpubmed-author:Homan van...lld:pubmed
pubmed-article:2564058pubmed:authorpubmed-author:EbelsTTlld:pubmed
pubmed-article:2564058pubmed:authorpubmed-author:EijgelaarAAlld:pubmed
pubmed-article:2564058pubmed:authorpubmed-author:KuntzeC ECElld:pubmed
pubmed-article:2564058pubmed:issnTypePrintlld:pubmed
pubmed-article:2564058pubmed:day11lld:pubmed
pubmed-article:2564058pubmed:volume1lld:pubmed
pubmed-article:2564058pubmed:ownerNLMlld:pubmed
pubmed-article:2564058pubmed:authorsCompleteYlld:pubmed
pubmed-article:2564058pubmed:pagination514-7lld:pubmed
pubmed-article:2564058pubmed:dateRevised2007-11-15lld:pubmed
pubmed-article:2564058pubmed:meshHeadingpubmed-meshheading:2564058-...lld:pubmed
pubmed-article:2564058pubmed:meshHeadingpubmed-meshheading:2564058-...lld:pubmed
pubmed-article:2564058pubmed:meshHeadingpubmed-meshheading:2564058-...lld:pubmed
pubmed-article:2564058pubmed:meshHeadingpubmed-meshheading:2564058-...lld:pubmed
pubmed-article:2564058pubmed:meshHeadingpubmed-meshheading:2564058-...lld:pubmed
pubmed-article:2564058pubmed:meshHeadingpubmed-meshheading:2564058-...lld:pubmed
pubmed-article:2564058pubmed:meshHeadingpubmed-meshheading:2564058-...lld:pubmed
pubmed-article:2564058pubmed:meshHeadingpubmed-meshheading:2564058-...lld:pubmed
pubmed-article:2564058pubmed:meshHeadingpubmed-meshheading:2564058-...lld:pubmed
pubmed-article:2564058pubmed:meshHeadingpubmed-meshheading:2564058-...lld:pubmed
pubmed-article:2564058pubmed:meshHeadingpubmed-meshheading:2564058-...lld:pubmed
pubmed-article:2564058pubmed:meshHeadingpubmed-meshheading:2564058-...lld:pubmed
pubmed-article:2564058pubmed:meshHeadingpubmed-meshheading:2564058-...lld:pubmed
pubmed-article:2564058pubmed:meshHeadingpubmed-meshheading:2564058-...lld:pubmed
pubmed-article:2564058pubmed:meshHeadingpubmed-meshheading:2564058-...lld:pubmed
pubmed-article:2564058pubmed:year1989lld:pubmed
pubmed-article:2564058pubmed:articleTitleRates of thromboembolism with three different mechanical heart valve prostheses: randomised study.lld:pubmed
pubmed-article:2564058pubmed:affiliationDepartment of Thoracic and Cardiovascular Surgery, University Hospital Groningen, The Netherlands.lld:pubmed
pubmed-article:2564058pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:2564058pubmed:publicationTypeClinical Triallld:pubmed
pubmed-article:2564058pubmed:publicationTypeComparative Studylld:pubmed
pubmed-article:2564058pubmed:publicationTypeRandomized Controlled Triallld:pubmed