Four peritoneal volume markers (carbon 14-labeled dextran, dextran blue, radioactive albumin, and hemoglobin) were compared. In six rabbits 14C-dextran was compared with dextran blue during a 4-hour "dwell" with a 4.25% dextrose solution. The recovery of 14C-dextran at the end of the dwell was 71% +/- 3% vs. 92% +/- 1% for dextran blue (P less than 0.001). In six other rabbits, radioactive albumin (RISA) was compared with dextran blue. The recovery of RISA was 78% +/- 4%, compared with 85% +/- 2% for dextran blue (P less than 0.05). The calculated peritoneal volumes, uncorrected for disappearance of the markers, were consistently higher than when correction was made. After correction, the calculated end volumes were similar to actually measured end volumes. In six patients with chronic ambulatory peritoneal dialysis, the intraperitoneal volume during a single dwell of 6 hours was estimated in paired observations with lactated Ringer's solution and 1.5% dextrose dialysate, using simultaneously autologous hemoglobin and RISA. In eight additional patients, a single dwell with 4.25% dextrose dialysate was studied. The recoveries of both markers were related to the osmotic strength of the dialysate. Recoveries were 66.7% +/- 2.3% and 69.6% +/- 0.9% in lactated Ringer's solution, and increased to 81% +/- 3% and 82% +/- 2% in 4.25% dextrose for hemoglobin and RISA, respectively. With each dialysate, after correction for disappearance of the marker, no differences in volume profiles or between calculated or measured end volumes could be found with either hemoglobin or RISA.(ABSTRACT TRUNCATED AT 250 WORDS)
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
AIM
|
pubmed:chemical |
http://linkedlifedata.com/resource/pubmed/chemical/Carbon Radioisotopes,
http://linkedlifedata.com/resource/pubmed/chemical/Dextrans,
http://linkedlifedata.com/resource/pubmed/chemical/Hemoglobins,
http://linkedlifedata.com/resource/pubmed/chemical/Indicators and Reagents,
http://linkedlifedata.com/resource/pubmed/chemical/Iodine Radioisotopes,
http://linkedlifedata.com/resource/pubmed/chemical/Serum Albumin,
http://linkedlifedata.com/resource/pubmed/chemical/blue dextran
|
pubmed:status |
MEDLINE
|
pubmed:month |
Apr
|
pubmed:issn |
0022-2143
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
111
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
421-9
|
pubmed:dateRevised |
2007-11-15
|
pubmed:meshHeading |
pubmed-meshheading:2450938-Animals,
pubmed-meshheading:2450938-Carbon Radioisotopes,
pubmed-meshheading:2450938-Dextrans,
pubmed-meshheading:2450938-Evaluation Studies as Topic,
pubmed-meshheading:2450938-Hemoglobins,
pubmed-meshheading:2450938-Humans,
pubmed-meshheading:2450938-Indicators and Reagents,
pubmed-meshheading:2450938-Iodine Radioisotopes,
pubmed-meshheading:2450938-Peritoneal Dialysis,
pubmed-meshheading:2450938-Serum Albumin
|
pubmed:year |
1988
|
pubmed:articleTitle |
Comparison of different volume markers in peritoneal dialysis.
|
pubmed:affiliation |
Department of Internal Medicine, University Hospital, Gent, Belgium.
|
pubmed:publicationType |
Journal Article,
Comparative Study
|